Validation of a smartphone-based Rinne test to detect an air-bone gap.

Hibscher Daniel, Oron Yahav, Handzel Ophir, Warshavsky Anton, Horowitz Gilad, Ungar Omer J

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To validate a smartphone-based Rinne test employing the vibration application of mobile telephones.

STUDY

DESIGN

Prospective controlled clinical study.

SETTING

Tertiary referral medical center.

METHODS

Twenty consecutive patients hospitalized in the otolaryngology department of a tertiary medical center due to unilateral hearing loss (HL study group), and 30 consecutive inpatients on the same ward who had no otological history (controls) were enrolled. Each participant underwent the traditional 512 Hz tuning fork-based Rinne test, as well as a smartphone-based Rinne test by means of a single uncovered smartphone with a vibration application. The test results were compared to those of formal audiometry.

RESULTS

The overall agreement between the traditional Rinne test and the smartphone-based test was 98%. The Sensitivity was 85% for both tests, specificity was 90% and 93% for smartphone and tuning fork tests, respectively. The smartphone-based Rinne test could correctly discriminate between patients with an air-bone gap ≥ 25 dB at 512 Hz from patients with a lower or no air-bone gap at 512 Hz. The smartphone-based Rinne could not evaluate two patients with a moderately severe/severe sensorineural hearing loss due to their inability to detect the vibrations.

CONCLUSION

A smartphone-based Rinne test was validated for the detection of an air-bone gap ≥ 25 dB at 512 Hz in the clinical setting. The validity of patient-operated smartphone-based Rinne test awaits further study.

LEVEL OF EVIDENCE: 2B.

Для цитирования: Hibscher Daniel, Oron Yahav, Handzel Ophir, Warshavsky Anton, Horowitz Gilad, Ungar Omer J. Validation of a smartphone-based Rinne test to detect an air-bone gap.. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 2021. DOI: 10.1007/s00405-021-06608-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.