MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2022.04.033

Медицинская библиотека · Heart rhythm · 2022

Left bundle branch area pacing in patients with atrioventricular conduction disease: A prospective multicenter study.

Raymond-Paquin Alexandre, Verma Atul, Kolominsky Jeffrey, Sanchez-Somonte Paula, Gul Enes Elvin, Pillai Ajay, Kron Jordana, Shepard Richard, Kalahasty Gautham, Tsang Bernice, Khaykin Yaariv, Pantano Alfredo, Koneru Jayanthi N, Ellenbogen Kenneth A

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The reported success rate of His-bundle pacing (HBP) in patients with infranodal atrioventricular (AV) conduction disease is only 52%-76%. The success rate of left bundle branch area pacing (LBBAP) in this cohort is not well studied.

OBJECTIVE

The purpose of this study was to evaluate the feasibility, safety, and electrophysiological characteristics of LBBAP in patients with AV conduction disease.

METHODS

Patients with AV conduction disease referred for pacemaker implantation at 2 centers between February 2019 and June 2021 were considered for LBBAP. Baseline demographic characteristics, procedural success rates, electrophysiological parameters, and complications were assessed.

RESULTS

LBBAP was successful in 340 of 364 patients (93%). Mean age was 72 ± 13 years, and mean follow-up was 331 ± 244 days. Pacing indications were Mobitz I in 27 patients (7%), Mobitz II or 2:1 AV block or high-grade AV block in 94 patients (26%), complete heart block in 199 patients (55%), and sick sinus syndrome with isolated bundle branch block in 44 patients (12%). Left bundle branch block and right bundle branch block were present in 57 patients (16%) and 140 patients (38%), respectively. Procedural success rates did not differ between indications (92.6%, 93.6%, 92.9%, and 95%, respectively) or between patients with narrow (<120 ms) vs wide QRS (≥120 ms). Mean LBBAP threshold was 0.77 ± 0.34 V at 0.4 ms at implant and remained stable during follow-up. There were 4 (1.2%) acute LBBAP lead dislodgments.

CONCLUSION

LBBAP is safe and feasible with high success rates for patients with AV conduction disease. In contrast to HBP, LBBAP success rates remain high over the entire spectrum of AV conduction disease, and lead parameters remain stable during follow-up.

Для цитирования: Raymond-Paquin Alexandre, Verma Atul, Kolominsky Jeffrey, Sanchez-Somonte Paula, Gul Enes Elvin, Pillai Ajay, Kron Jordana, Shepard Richard, Kalahasty Gautham, Tsang Bernice, Khaykin Yaariv, Pantano Alfredo, Koneru Jayanthi N, Ellenbogen Kenneth A. Left bundle branch area pacing in patients with atrioventricular conduction disease: A prospective multicenter study.. Heart rhythm. 2022. DOI: 10.1016/j.hrthm.2022.04.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.