MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000002295

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2025

Successful Extracorporeal Cardiopulmonary Resuscitation Despite Aortic Occlusion.

Becker Torben K, Bruno John, Jeng Eric I, Phillips Jordan, Smith Taylor N, Roberts David L, Carr Casey T, Cooper Michol A, Back Martin R, Anderson R David, Maybauer Marc O

СтатьяКлинический случайПеревод пока не подготовлен

Аннотация

We present the case of a 62-year-old man with severe coronary artery disease who presented to the hospital in refractory ventricular fibrillation cardiac arrest. He showed signs of life despite prolonged resuscitation. We thus decided to initiate extracorporeal cardiopulmonary resuscitation (ECPR). The patient had a known total occlusion of his infrarenal aorta that had been surgically bypassed with a bifemoral-axillary graft. We successfully initiated ECPR via the surgical graft, establishing blood flow to the central circulation through the axillary artery in a peripheral configuration while ensuring blood flow to the left leg via the femoral-femoral graft. The patient was extubated neurologically intact the following day and subsequently underwent coronary artery bypass graft surgery while on extracorporeal membrane oxygenation (ECMO) support. He was subsequently weaned off inotropic support and decannulated from ECMO. He was discharged home neurologically intact and independent in his activities of daily living. This case demonstrates that cannulation for ECPR via a surgical vascular graft is possible and that a total occlusion of the infrarenal aorta in the presence of a surgical bypass is not an absolute contraindication to ECMO.

Для цитирования: Becker Torben K, Bruno John, Jeng Eric I, Phillips Jordan, Smith Taylor N, Roberts David L, Carr Casey T, Cooper Michol A, Back Martin R, Anderson R David, Maybauer Marc O. Successful Extracorporeal Cardiopulmonary Resuscitation Despite Aortic Occlusion.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2025. DOI: 10.1097/mat.0000000000002295.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.