MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtha.2024.02.007

Медицинская библиотека · Journal of thrombosis and haemostasis : JTH · 2024

A specific fluorescence resonance energy quenching-based biosensor for measuring thrombin activity in whole blood.

Dai Ying, Kretz Colin A, Kim Paul Y, Gross Peter L

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

At sites of vessel injury, thrombin acts as the central mediator of coagulation by catalyzing fibrin clot formation and platelet activation. Thrombin generation is most frequently measured in plasma samples using small-molecule substrates; however, these have low specificity for thrombin and limited utility in whole blood. Plasma assays are limited because they ignore the hemostatic contributions of blood cells and require anticoagulation and the addition of supraphysiological concentrations of calcium.

OBJECTIVES

To overcome these limitations, we designed and characterized a fluorescence resonance energy quenching-based thrombin sensor (FTS) protein.

METHODS

The fluorescence resonance energy quenching pair of mAmetrine and tTomato, separated by a thrombin recognition sequence, was developed. The protein was expressed using Escherichia coli, and purity was assessed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis. The cleavage of FTS was monitored by fluorescence using excitation at 406 nm and emission at 526 nm and 581 nm.

RESULTS

Compared with small-molecule substrates, the FTS demonstrated high specificity for thrombin; it is not cleaved by thrombin or inhibited by α2-macroglobulin and interacts with thrombin's anion-binding exosite I. The FTS can effectively measure thrombin generation in plasma and in finger-prick whole blood, which allows it to be developed into a point-of-care test of thrombin generation. The FTS does not inhibit standard thrombin-generation assays. Lastly, FTS-based thrombin generation in nonanticoagulated finger-prick blood was delayed but enhanced compared with that in citrated plasma.

CONCLUSION

The FTS will broaden our understanding of thrombin generation in ways that are not attainable with current methods.

Для цитирования: Dai Ying, Kretz Colin A, Kim Paul Y, Gross Peter L. A specific fluorescence resonance energy quenching-based biosensor for measuring thrombin activity in whole blood.. Journal of thrombosis and haemostasis : JTH. 2024. DOI: 10.1016/j.jtha.2024.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.