Transcatheter aortic valve implantation complexity score.

Abdelrahman Amr, Bamford Paul, Aktaa Suleman, Hall Rowan, Arockiam Sacchin, Blackman Daniel J, Malkin Christopher, Cunnington Michael, Ali Noman

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Increasing demand for transcatheter aortic valve implantation (TAVI) places greater emphasis on the efficiency of pathways and services. A significant limitation to increasing TAVI capacity is the availability of cardiac catheterisation laboratory time. We have developed a novel complexity scoring system (TAVI ComplEXity; TEX score) which can aid in planning lists with appropriate case selection. To validate the TEX score, we have undertaken a retrospective analysis of TAVI cases. The hypothesis is that increasing TEX score correlates with increased procedural duration and reduced valve academic research consortium (VARC) 3 technical and device success.

METHODS

The TEX score assigns patients to a complexity level of 1 (low), 2 (intermediate) or 3 (high) based on the presence of specific clinical and anatomical variables. For validation purposes, comparisons were made between patients in the three complexity levels with respect to procedural duration as well as VARC-3 technical success, device success and early safety.

RESULTS

The validation study included 1034 consecutive patients who underwent TAVI between June 2021 and October 2023. Of these, 582 (56.3%) were classified as level 1 complexity, 377 (36.5%) level 2 and 75 (7.3%) level 3. Significant differences were observed between the three groups with respect to procedural duration (73.7 min vs 85.6 min vs 136 min; p<0.001), VARC-3 technical success (97.9% vs 96.6% vs 92%; p<0.05) and VARC-3 device success (96.2% vs 92.3% vs 86.6%; p<0.001).

CONCLUSION

The TEX score is a simple tool which allows stratification of patients into three levels of complexity. Increasing complexity levels correlate with increasing procedural duration and reduced VARC-3 technical and device success. This is potentially useful for scheduling patients onto appropriate lists.

Для цитирования: Abdelrahman Amr, Bamford Paul, Aktaa Suleman, Hall Rowan, Arockiam Sacchin, Blackman Daniel J, Malkin Christopher, Cunnington Michael, Ali Noman. Transcatheter aortic valve implantation complexity score.. Open heart. 2025. DOI: 10.1136/openhrt-2024-002804.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.