MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2459/jcm.0000000000001597

Медицинская библиотека · Journal of cardiovascular medicine (Hagerstown, Md.) · 2024

Diastolic dysfunction and clinical outcomes after transcatheter or surgical aortic valve replacement in patients with atypical aortic valve stenosis.

Belin Rashad J, Desa Travis B, Wroblewski Igor, Joyce Cara, Perez-Tamayo Anthony, Schwartz Jeffrey, Steen Lowell H, Lopez John J, Lewis Bruce E, Leya Ferdinand S, Tuchek Michael, Bakhos Mamdouh, Mathew Verghese

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Diastolic dysfunction is a predictor of poor outcomes in many cardiovascular conditions. At present, it is unclear whether diastolic dysfunction predicts adverse outcomes in patients with atypical aortic stenosis who undergo aortic valve replacement (AVR).

METHODS

Five hundred and twenty-three patients who underwent transcatheter AVR (TAVR) (n = 303) and surgical AVR (SAVR) (n = 220) at a single institution were included in our analysis. Baseline left and right heart invasive hemodynamics were assessed. Baseline transthoracic echocardiograms were reviewed to determine aortic stenosis subtype and parameters of diastolic dysfunction. Aortic stenosis subtype was categorized as typical (normal flow, high-gradient) aortic stenosis, classical, low-flow, low-gradient (cLFLG) aortic stenosis, and paradoxical, low-flow, low-gradient (pLFLG) aortic stenosis. Cox proportional hazard models were utilized to examine the relation between invasive hemodynamic or echocardiographic variables of diastolic dysfunction, aortic stenosis subtype, and all-cause mortality. Propensity-score analysis was performed to study the relation between aortic stenosis subtype and the composite outcome [death/cerebrovascular accident (CVA)].

RESULTS

The median STS risk was 5.3 and 2.5% for TAVR and SAVR patients, respectively. Relative to patients with typical aortic stenosis, patients with atypical (cLFLG and pLFLG) aortic stenosis displayed a significantly higher prevalence of diastolic dysfunction (LVEDP ≥ 20mmHg, PCWP ≥ 20mmHg, echo grade II or III diastolic dysfunction, and echo-PCWP ≥ 20mmHg) and, independently of AVR treatment modality, had a significantly increased risk of death. In propensity-score analysis, patients with atypical aortic stenosis had higher rates of death/CVA than typical aortic stenosis patients, independently of diastolic dysfunction and AVR treatment modality.

CONCLUSION

We demonstrate the novel observation that compared with patients with typical aortic stenosis, patients with atypical aortic stenosis have a higher burden of diastolic dysfunction. We corroborate the worse outcomes previously reported in atypical versus typical aortic stenosis and demonstrate, for the first time, that this observation is independent of AVR treatment modality. Furthermore, the presence of diastolic dysfunction does not independently predict outcome in atypical aortic stenosis regardless of treatment type, suggesting that other factors are responsible for adverse clinical outcomes in this higher risk cohort.

Для цитирования: Belin Rashad J, Desa Travis B, Wroblewski Igor, Joyce Cara, Perez-Tamayo Anthony, Schwartz Jeffrey, Steen Lowell H, Lopez John J, Lewis Bruce E, Leya Ferdinand S, Tuchek Michael, Bakhos Mamdouh, Mathew Verghese. Diastolic dysfunction and clinical outcomes after transcatheter or surgical aortic valve replacement in patients with atypical aortic valve stenosis.. Journal of cardiovascular medicine (Hagerstown, Md.). 2024. DOI: 10.2459/jcm.0000000000001597.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.