Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice: one-yearresults of the ACURATE neo2 PMCF Study.

Kim Won-Keun, Möllmann Helge, Montorfano Matteo, Ellert-Gregersen Julia, Rudolph Tanja K, Van Mieghem Nicolas M, Hilker Michael, Amat-Santos Ignacio, Terkelsen Christian Juhl, Petronio Anna Sonia, Stella Pieter, Götberg Matthias, Rück Andreas, Kasel A Markus, Trillo Ramiro, Appleby Clare, Barbanti Marco, Blanke Philipp, Asch Federico M, Modolo Rodrigo, Allocco Dominic J, Tamburino Corrado

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation.

AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting.

METHODS

Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography).

RESULTS

The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL).

CONCLUSIONS

The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).

Для цитирования: Kim Won-Keun, Möllmann Helge, Montorfano Matteo, Ellert-Gregersen Julia, Rudolph Tanja K, Van Mieghem Nicolas M, Hilker Michael, Amat-Santos Ignacio, Terkelsen Christian Juhl, Petronio Anna Sonia, Stella Pieter, Götberg Matthias, Rück Andreas, Kasel A Markus, Trillo Ramiro, Appleby Clare, Barbanti Marco, Blanke Philipp, Asch Federico M, Modolo Rodrigo, Allocco Dominic J, Tamburino Corrado. Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice: one-yearresults of the ACURATE neo2 PMCF Study.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2024. DOI: 10.4244/eij-d-23-00823.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.