OBJECTIVES
Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration.
METHODS
In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration.
RESULTS
In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001).
CONCLUSIONS
High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.