MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eij-d-23-00456

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2023

Long-term outcomes of measured and predicted prosthesis-patient mismatch following transcatheter aortic valve replacement.

Tomii Daijiro, Okuno Taishi, Heg Dik, Nakase Masaaki, Lanz Jonas, Praz Fabien, Stortecky Stefan, Reineke David, Windecker Stephan, Pilgrim Thomas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Both measured and predicted effective orifice area (EOA) indexed to the body surface area (EOAi) have been suggested to define prosthesis-patient mismatch (PPM) in patients undergoing transcatheter aortic valve replacement (TAVR). The impact of PPM on clinical outcomes may accumulate with extended follow-up and vary according to the definition used.

AIMS: We aimed to investigate the long-term clinical impact of PPM in patients undergoing TAVR.

METHODS

Patients in a prospective TAVR registry were stratified by the presence of moderate (0.65-0.85 or 0.55-0.70 cm2/m2 if obese) or severe (≤0.65 or ≤0.55 cm2/m2 if obese) PPM according to echocardiographically measured EOAi (measured PPM), predicted EOAi based on published EOA reference values for each valve model and size (predicted PPMTHV), or predicted EOAi based on EOA reference values derived from computed tomography measurements of aortic annulus dimensions (predicted PPMCT).

RESULTS

In an analysis of 2,463 patients, the frequency of measured PPM (moderate: 27.0%; severe: 8.7%) was higher than the frequency of predicted PPMTHV (moderate: 11.3%; severe: 1.2%) or predicted PPMCT (moderate: 12.0%; severe: 0.1%). During a median follow-up of 429 days, 10-year mortality was comparable in patients with versus without measured PPM or predicted PPMCT. In contrast, patients with moderate predicted PPMTHV had a lower risk of 10-year all-cause mortality compared with those without PPM (adjusted hazard ratio: 0.73, 95% confidence interval: 0.55-0.96).

CONCLUSIONS

The use of predicted versus measured EOAi results in a lower estimate of PPM severity. We observed no increased risk of death in patients with PPM over a median follow-up time of 429 days.

CLINICALTRIALS: gov: NCT01368250.

Для цитирования: Tomii Daijiro, Okuno Taishi, Heg Dik, Nakase Masaaki, Lanz Jonas, Praz Fabien, Stortecky Stefan, Reineke David, Windecker Stephan, Pilgrim Thomas. Long-term outcomes of measured and predicted prosthesis-patient mismatch following transcatheter aortic valve replacement.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2023. DOI: 10.4244/eij-d-23-00456.