MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcvm.2021.799285

Медицинская библиотека · Frontiers in cardiovascular medicine · 2022

Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve.

Kameshima Haruka, Izumo Masaki, Suzuki Tomomi, Ohara Hiroshi, Sato Yukio, Watanabe Mika, Kuwata Shingo, Okuyama Kazuaki, Kamijima Ryo, Takai Manabu, Kou Seisyou, Tanabe Yasuhiro, Harada Tomoo, Akashi Yoshihiro J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

There is no evidence of hemodynamic performance during exercise in patients with aortic stenosis (AS) after transcatheter aortic valve implantation (TAVI). This study aimed to investigate the changes in kinematic hemodynamics during exercise and determine the impact of prosthesis-patient mismatch (PPM) on the hemodynamics of transcatheter heart valves using exercise stress echocardiography (ESE) in AS patients after TAVI.

METHODS AND

RESULTS

This study enrolled 77 consecutive patients (mean age 82 ± 5 years, 50.6% male) who underwent ESE 3-6 months after TAVI with a balloon-expandable valve. The effective orifice area index at rest was significantly correlated with the mean pressure gradient (PG) during exercise (p <0.001). The patients were divided into two groups according to the presence of PPM (PPM and non-PPM groups). During exercise, the patients with PPM had a higher left ventricular ejection fraction (74.6 ± 6.1% vs. 69.7 ± 9.6%, p = 0.048), a lower stroke volume index (47.2 ± 14.0 ml/m2 vs. 55.6 ± 14.5 ml/m2, p = 0.037), a significantly higher mean transvalvular PG (21.9 ± 9.1 mmHg vs. 12.2 ± 4.9 mmHg, p = 0.01) and an increased mean PG from rest to exercise (5.7 ± 3.5 mmHg vs. 2.3 ± 2.8 mmHg, p <0.001) compared with patients without PPM. Patients with PPM had a higher pulmonary artery systolic pressure (SPAP) during exercise (57.3 ± 13.8 mmHg vs. 49.7 ± 10.9 mmHg, p = 0.021) and a higher incidence of exercise-induced pulmonary hypertension (43.8 vs. 15.0%, p = 0.037) than patients without PPM. PPM was strongly associated with exercise-induced pulmonary hypertension (hazard ratio: 3.570, p = 0.013).

CONCLUSIONS

AS patients with PPM after TAVI showed a disproportionate increase in the transvalvular PG and SPAP during exercise, and PPM was associated with exercise-induced pulmonary hypertension.

Для цитирования: Kameshima Haruka, Izumo Masaki, Suzuki Tomomi, Ohara Hiroshi, Sato Yukio, Watanabe Mika, Kuwata Shingo, Okuyama Kazuaki, Kamijima Ryo, Takai Manabu, Kou Seisyou, Tanabe Yasuhiro, Harada Tomoo, Akashi Yoshihiro J. Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve.. Frontiers in cardiovascular medicine. 2022. DOI: 10.3389/fcvm.2021.799285.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.