18F-GP1 Positron Emission Tomography and Bioprosthetic Aortic Valve Thrombus.

Bing Rong, Deutsch Marcus-André, Sellers Stephanie L, Corral Carlos Alcaide, Andrews Jack P M, van Beek Edwin J R, Bleiziffer Sabine, Burchert Wolfgang, Clark Tim, Dey Damini, Friedrichs Kai, Gummert Jan F, Koglin Norman, Leipsic Jonathon A, Lindner Oliver, MacAskill Mark G, Milting Hendrik, Pessotto Renzo, Preuss Rainer, Raftis Jennifer B, Rudolph Tanja K, Rudolph Volker, Slomka Piotr, Stephens Andrew W, Tavares Adriana, Tzolos Evangelos, Weir Nick, White Audrey C, Williams Michelle C, Zabel Reinhard, Dweck Marc R, Hugenberg Verena, Newby David E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Bioprosthetic valve thrombosis may have implications for valve function and durability.

OBJECTIVES

Using a novel glycoprotein IIb/IIIa receptor radiotracer 18F-GP1, we investigated whether positron emission tomography (PET)-computed tomography (CT) could detect thrombus formation on bioprosthetic aortic valves.

METHODS

Ex vivo experiments were performed on human platelets and explanted bioprosthetic aortic valves. In a prospective cross-sectional study, patients with either bioprosthetic or normal native aortic valves underwent echocardiography, CT angiography, and 18F-GP1 PET-CT.

RESULTS

Flow cytometric analysis, histology, immunohistochemistry, and autoradiography demonstrated selective binding of 18F-GP1 to activated platelet glycoprotein IIb/IIIa receptors and thrombus adherent to prosthetic valves. In total, 75 participants were recruited: 53 with bioprosthetic valves (median time from implantation 37 months [IQR: 12-80 months]) and 22 with normal native aortic valves. Three participants had obstructive valve thrombosis, and a further 3 participants had asymptomatic hypoattenuated leaflet thickening on CT angiography. All bioprosthetic valves, but none of the native aortic valves, demonstrated focal 18F-GP1 uptake on the valve leaflets: median maximum target-to-background ratio 2.81 (IQR: 2.29-3.48) vs 1.43 (IQR: 1.28-1.53) (P < 0.001). Higher 18F-GP1 uptake was independently associated with duration of valve implantation and hypoattenuated leaflet thickening. All 3 participants with obstructive valve thrombosis were anticoagulated for 3 months, leading to resolution of their symptoms, improvement in mean valve gradients, and a reduction in 18F-GP1 uptake.

CONCLUSIONS

Adherence of activated platelets is a common and sustained finding on bioprosthetic aortic valves. 18F-GP1 uptake is higher in the presence of thrombus, regresses with anticoagulation, and has potential use as an adjunctive clinical tool. (18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis; NCT04073875).

Для цитирования: Bing Rong, Deutsch Marcus-André, Sellers Stephanie L, Corral Carlos Alcaide, Andrews Jack P M, van Beek Edwin J R, Bleiziffer Sabine, Burchert Wolfgang, Clark Tim, Dey Damini, Friedrichs Kai, Gummert Jan F, Koglin Norman, Leipsic Jonathon A, Lindner Oliver, MacAskill Mark G, Milting Hendrik, Pessotto Renzo, Preuss Rainer, Raftis Jennifer B, Rudolph Tanja K, Rudolph Volker, Slomka Piotr, Stephens Andrew W, Tavares Adriana, Tzolos Evangelos, Weir Nick, White Audrey C, Williams Michelle C, Zabel Reinhard, Dweck Marc R, Hugenberg Verena, Newby David E. 18F-GP1 Positron Emission Tomography and Bioprosthetic Aortic Valve Thrombus.. JACC. Cardiovascular imaging. 2022. DOI: 10.1016/j.jcmg.2021.11.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.