MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2021.11.013

Медицинская библиотека · Journal of cardiovascular computed tomography · 2021

The impact of hypo-attenuated leaflet thickening on haemodynamic valve deterioration following transcatheter aortic valve replacement.

Rashid Hashrul N, Michail Michael, Ramnarain Jaineel, Nasis Arthur, Nicholls Stephen J, Cameron James D, Gooley Robert P

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Hypo-attenuated leaflet thickening (HALT) may occur following transcatheter aortic valve replacement (TAVR), however, it remains unclear if HALT is a predictor of haemodynamic valve deterioration (HVD).

AIM: To determine the impact of HALT on the occurrence of HVD.

METHODS

We prospectively evaluated 186 patients for the presence of HALT at a median of 6 weeks following TAVR (Interquartile-range [IQR] 4-12 weeks). HALT depth and area were measured. HVD encompassed any of the following: mean gradient ≥20 ​mmHg with an increase in gradient ≥10 ​mmHg from baseline, Doppler velocity index reduction ≥0.1 or new moderate-to-severe valvular regurgitation. Routine echocardiograms at discharge, one month and annually, were assessed by echo-cardiologists that were blinded to the HALT status.

RESULTS

LT prevalence was 17.7% (33/186). HVD was present in 8.6% (16/186) at a median follow-up of 2 years (IQR 1-3); two required valve re-intervention and five required anticoagulation. HALT was the only independent predictor of HVD on multivariate analysis (OR 33.3, 95%CI 7.4-125). Patients with HALT were more likely to develop HVD, require repeat valve intervention and have higher trans-valvular gradients at up to 3-year follow-up. Patients with HALT had a median cumulative thickness of 2.9 ​mm (IQR 1.9-4.7) and area of 64.2 ​mm2 (IQR 40.9-91.6). Thresholds for HALT in predicting HVD were a cumulative depth of 2.4 ​mm (Specificity 94.1%, Sensitivity 75.0%, AUC ​= ​0.87) and cumulative area of 28 ​mm2 (Specificity 92.2%, Sensitivity 81.3%, AUC ​= ​0.86).

CONCLUSION

HALT is an independent predictor of HVD, which exhibits specific depth and area thresholds to predict HVD. CT following TAVR may determine patients at risk of HVD.

Для цитирования: Rashid Hashrul N, Michail Michael, Ramnarain Jaineel, Nasis Arthur, Nicholls Stephen J, Cameron James D, Gooley Robert P. The impact of hypo-attenuated leaflet thickening on haemodynamic valve deterioration following transcatheter aortic valve replacement.. Journal of cardiovascular computed tomography. 2021. DOI: 10.1016/j.jcct.2021.11.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.