m+Medelevator.RU
← Поиск публикаций
Ophthalmology · 2005

Sensitivity and specificity of the StratusOCT for perimetric glaucoma.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Budenz Donald L, Michael Anika, Chang Robert T, McSoley John, Katz Joanne

Аннотация

PURPOSE: To determine the sensitivity and specificity of measurements of the retinal nerve fiber layer (RNFL) using the StratusOCT in glaucoma subjects with visual field (VF) defects.

DESIGN: Prospective cross-sectional study.

PARTICIPANTS: One hundred nine normal and 63 glaucoma subjects.

TESTING: Fast RNFL scans were performed in one eye of each patient using the StratusOCT.

MAIN OUTCOME MEASURES: Sensitivity and specificity of different optical coherence tomography (OCT) criteria for identifying glaucoma subjects with glaucomatous VF defects.

SECONDARY OUTCOME MEASURES: Areas under the receiver operating characteristic curves (AROCs) for various OCT parameters.

RESULTS: Severity of VF defects in the glaucoma group was distributed between mild (18 subjects), moderate (21 subjects), and severe (24 subjects). The average mean deviation of the glaucoma fields was -8.4 decibels (dB), with a standard deviation of 6.0 dB and a range from -0.14 to -28.0 dB. The sensitivity and specificity using a criterion of average RNFL thickness abnormal at the <5% level were 84% and 98%, respectively. The sensitivity and specificity using a criterion of average RNFL thickness abnormal at the <1% level were 68% and 100%. The sensitivity and specificity of using a criterion of >or=1 quadrants abnormal at the <5% level were 89% and 95%. The sensitivity and specificity of using a criterion of >or=1 quadrants abnormal at the <1% level were 83% and 100%. The sensitivity and specificity of using a criterion of >or=1 clock hours abnormal at the <5% level were 89% and 92%. The sensitivity and specificity of using a criterion of >or=1 quadrants abnormal at the <1% level were 83% and 100%. The AROC for mean RNFL thickness was 0.966. Other high AROC values included the superior quadrant (0.952), inferior quadrant (0.971), inferotemporal clock hour at 7-o'clock (right eye) and 5-o'clock (left eye) (0.959), 6-o'clock hour (0.940), superotemporal clock hour at 11-o'clock (right eye) and 1-o'clock (left eye) (0.935), and 12-o'clock hour (0.924).

CONCLUSIONS: The sensitivity and specificity of RNFL measurements using the new StratusOCT for glaucoma with manifest VF defects are excellent. The best parameters seem to be >or=1 quadrants abnormal at the <or=5% level or >or=1 clock hours abnormal at the <or=5% level. Future studies are needed to determine the sensitivity and specificity of this new technology for glaucoma without VF defects.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты