Contact trans-scleral diode laser cyclophotocoagulation treatment for refractory glaucomas in the Indian population.

Gupta V, Agarwal H C

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to evaluate the clinical efficacy of contact diode trans-scleral cyclophotocoagulation (TSCPC) for treatment of refractory glaucomas.

METHOD: Fifty two eyes of 52 patients, (post-penetrating keratoplasty glaucoma: 16 eyes; adherent leucoma with secondary glaucoma: 8 eyes; aphakic glaucoma: 6 eyes; neovascular glaucoma: 6 eyes; narrow angle glaucoma: 6 eyes; and other secondary glaucomas: 10 eyes) were followed up from 3.5-18 months (average 12 months) after TSCPC. The treatment parameters using the contact G probe were--energy: 3-4J; area: 40 spots spread over 360 degrees; site: 1.2-1.5 mm posterior to limbus. Retreatments (22 eyes; 42%) were given whenever intraocular pressure (IOP) exceeded 22 mmHg despite maximum tolerable topical therapy.

RESULTS

IOP decreased from a baseline of 44.7 (+/- 7.3) mmHg to 15 (+/- 3.7) mmHg at first week and was 15.2 +/- (8.2) mmHg at the last follow up. Successful control of IOP (< 22 mmHg) occurred in 30 (58%) eyes after a single treatment and in 48 (92%) eyes following retreatment. Complications included reduction in visual acuity from light perception (LP) only to no light perception (NLP) in two eyes and phthisis bulbi in one eye.

CONCLUSION

Contact trans-scleral diode laser cyclophotocoagulation is effective in lowering IOP in eyes with intractable glaucoma with few side effects in Indian subjects.

Для цитирования: Gupta V, Agarwal H C. Contact trans-scleral diode laser cyclophotocoagulation treatment for refractory glaucomas in the Indian population.. Indian journal of ophthalmology. 2000.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.