Journal of cardiovascular electrophysiology · 1997

Implantable cardioverter defibrillator utilization among device recipients presenting exclusively with syncope or near-syncope.

Клиническое исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Militianu A, Salacata A, Seibert K, Kehoe R, Baga J J, Meissner M D, Pires L A, Schuger C D, Steinman R T, Mosteller R D, Palti A J, David J B, Lessmeier T J, Lehmann M H

Аннотация

INTRODUCTION: Implantable cardioverter defibrillators (ICDs) are occasionally used in presumed high-risk patients with electrocardiographically undocumented syncope, although the incidence of ventricular tachyarrhythmias in this population is not well defined.

METHODS AND RESULTS: We studied 33 consecutive patients receiving an ICD (67% nonthoracotomy and 70% tiered therapy) after electrophysiologic testing for unmonitored "syncope" (n = 29) or "near-syncope" (n = 4). Atherosclerotic heart disease was present in 24 (73%); mean left ventricular ejection fraction (LVEF) was 0.39 +/- 0.15; and sustained monomorphic ventricular tachycardia (SMVT) was inducible in 18 (55%). Over a median follow-up of 17 months (range 4 to 61), 12 patients (36%) received > or = 1 appropriate ICD discharge triggered by SMVT (cycle length 230 to 375 msec) in 10 and ventricular flutter or fibrillation in 2--without concomitant antiarrhythmic medication in 8 of 12 cases. Inducible SMVT and LVEF < or = 0.35 were statistically significant, independent predictors of an appropriate ICD discharge (P < 0.02 and P < 0.03, respectively). Estimated 1-year cumulative survival free of appropriate discharge was 34% versus 87%, respectively, in patients with versus without inducible SMVT (P < 0.02), and 18% versus 56%, respectively, in patients with LVEF < or = 0.35 versus LVEF > 0.35 (P < 0.03).

CONCLUSION: In this highly select, multicenter population of ICD recipients with electrocardiographically undocumented syncope, a substantial incidence of appropriate device discharges was observed, particularly in patients with inducible SMVT and LVEF < or = 0.35. These findings support the notion that, in patients with LV dysfunction and inducible SMVT, ventricular tachyarrhythmias are likely to account for episodes of syncope or near-syncope.