BACKGROUND

To develop and validate various models to predict total keratometry (TK) power vector components TKC0 and TKC45 from classical keratometry (K) KC0 and KC45 based on a large dataset of pre cataract surgery IOLMaster 700 measurements.

METHODS

Retrospective cross-sectional multicentric study evaluating a dataset containing 13 6378 IOLMaster 700 measurements including K and TK. Left eyes were mirrored about the facial axis. Based on 80% training data, we developed a global and segmented constant model (CM and CMS), a global and segmented (according to the angle A1 of the flat keratometric meridian) linear model (LM and LMS), a harmonic model (HM) and compared these to a classical constant (CMR) and linear models (LMR) segmented into with-the-rule, against-the-rule and oblique astigmatism. The performance was cross-validated using the root-mean-squared model fit error (RMSE).

RESULTS

In the 20% test data, RMSE was 0.173 D before correction and was reduced by 40%-42% to 0.100 and 0.104 D with the correction models. The segmented models performed slightly better than the global models, and the linear models performed slightly better than the constant models. With the individually adjusted changepoints, the CMS and LMS performed slightly better than the reference models CMR and LMR. There was no systematic difference between the RMSE with training and test data, indicating no overfit of the models.

CONCLUSION

As the performance is quite similar for all tested correction models, we recommend using a simple global constant model to predict TK vector components. This could easily be implemented in any consumer software.

Для цитирования: Langenbucher Achim, Hoffmann Peter, Cayless Alan, Szentmáry Nóra, Riaz Kamran, Gatinel Damien, Findl Oliver, Pantanelli Seth, Yeo Tun Kuan, Savini Giacomo, Wendelstein Jascha. Predictive Correction Model for Corneal Back Surface Astigmatism With IOLMaster700 Keratometry Data in a Cataractous Population.. Clinical & experimental ophthalmology. 2025. DOI: 10.1111/ceo.70009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.