MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.str.0000019290.25405.83

Медицинская библиотека · Stroke · 2002

Imaging of distal internal carotid artery by ultrasonography with a 3.5-MHz convex probe.

Todo Kenichi, Watanabe Manabu, Fukunaga Ryuzo, Araki Ken, Yamamoto Shiro, Rai Makiko, Hoshi Taku, Nukata Masaru, Taguchi Akihiko, Kinoshita Naokazu

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Conventionally, carotid ultrasonography has been performed with a 7.5-MHz linear probe to evaluate the extracranial internal carotid artery (ICA). However, usually only the carotid bulb or proximal portion of the ICA can be evaluated. We attempted to evaluate the distal extracranial ICA with a 3.5-MHz convex probe.

METHODS

The subjects were 17 consecutive patients with ICAs free of occlusive disease and 3 other patients with distal extracranial ICA stenosis. Using a 7.5-MHz linear probe and a 3.5-MHz convex probe, we performed long-axis B-mode imaging of the ICAs to evaluate the distance between the distal limit of visualized ICA and the bifurcation of the common carotid artery.

RESULTS

The distal limit of the ICA, visualized with a 7.5- or a 3.5-MHz probe, was 31+/-11 or 57+/-8 mm distal to the common carotid artery bifurcation, respectively. In the 3 patients with distal extracranial ICA stenosis, the lesion could be successfully diagnosed with only the 3.5-MHz probe.

CONCLUSIONS

This form of carotid imaging is feasible and may be potentially useful in the evaluation of carotid disease.

Для цитирования: Todo Kenichi, Watanabe Manabu, Fukunaga Ryuzo, Araki Ken, Yamamoto Shiro, Rai Makiko, Hoshi Taku, Nukata Masaru, Taguchi Akihiko, Kinoshita Naokazu. Imaging of distal internal carotid artery by ultrasonography with a 3.5-MHz convex probe.. Stroke. 2002. DOI: 10.1161/01.str.0000019290.25405.83.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.