MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacadv.2025.102236

Медицинская библиотека · JACC. Advances · 2025

Favorable Effects of Atrial Fixation Transcatheter Mitral Valve Replacement on Left Atrium Volume and Strain.

Hamid Nadira, Grayburn Paul, Ninios Vlasis, Wrobel Krzysztof, Tahirkheli Naeem, Waksman Ron, Rinaldi Michael, Grygier Marek, Genereux Philippe, Sorajja Paul

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The AltaValve System transcatheter mitral valve replacement (TMVR) has a spherical nitinol frame designed to fit the left atrium (LA) in a compliant fashion.

OBJECTIVES

The objective of the study was to evaluate the anatomical and functional changes of the LA with the AltaValve System.

METHODS

A total of 16 patients with severe, symptomatic mitral regurgitation who underwent AltaValve System transcatheter mitral valve replacement implantation via either a transseptal (n = 8) or transapical (n = 8) approach were examined. Transthoracic echocardiography was performed at baseline and 6-month follow-up. LA volumes and strain were evaluated using dedicated software (TomTec) with paired statistical testing.

RESULTS

All patients (median age, 77 years; 75% women [12/16]) had successful implantation. Most had atrial fibrillation (87%) and normal/reduced left ventricular ejection fraction. There was significant reduction in LA volume at 6 months (117.4 ± 39 mL vs 93.0 ± 37.0 mL; P = 0.002). For LA strain, there was significant reduction in both reservoir (10.8% ± 5.8% vs 1.6% ± 2.1%; P < 0.001) and conduit phase (-9.7% ± 3.2% vs -4.2% ± 4.4%; P = 0.013) of LA cycle. There were no significant change in the contraction phase (-1.1% vs -2.7%; P = 0.079). There was significant improvement in exercise capacity among 13 patients (average 6-minute walk test distance from 253 m at baseline to 296 m) and in functional status 55.1 ± 20.5 at baseline to 67.0 ± 22.5 (P = 0.04) at 6-month follow-up. For the responders, there were statistically significant differences at 6-month follow-up for majority of the LA parameters including strain.

CONCLUSIONS

There was a presence of LA remodeling following AltaValve System implantation and this was accompanied by a reduction in LA strain for both the reservoir and conduit phases, without changes in contractility.

Для цитирования: Hamid Nadira, Grayburn Paul, Ninios Vlasis, Wrobel Krzysztof, Tahirkheli Naeem, Waksman Ron, Rinaldi Michael, Grygier Marek, Genereux Philippe, Sorajja Paul. Favorable Effects of Atrial Fixation Transcatheter Mitral Valve Replacement on Left Atrium Volume and Strain.. JACC. Advances. 2025. DOI: 10.1016/j.jacadv.2025.102236.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.