MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ohn.70033

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2025

Validation of the Hearing Utility Measure (HUM) in Cochlear Implant Candidates and Users.

Dixon Peter R, Shah Anuja H, McRackan Theodore R, Feeny David, Cushing Sharon L, Tomlinson George, Chen Joseph M

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To validate the Hearing Utility Measure (HUM), a tool designed to quantify hearing loss impact on health and quality of life for use in economic evaluation.

STUDY

DESIGN

Prospective cohort.

SETTING

Tertiary academic center.

METHODS

Cochlear implant (CI) candidates were enrolled between June 25, 2020, and March 17, 2024. Participants completed HUM alongside other assessments, including Health Utilities Index, Mark-3 (HUI-3), Speech, Spatial and Qualities of Hearing Scale (SSQ-49), Cochlear Implant Quality of Life Profile (CIQOL-35), and Tinnitus Handicap Inventory (THI) at the time of CI evaluation and 12 months post-activation. A subgroup with stable hearing status completed HUM twice, 6 months apart, to assess test-retest reliability.

RESULTS

Among 1315 participants, HUM showed strong correlations with CIQOL-global (r = 0.69; 95% CI: 0.66-0.72) and SSQ-overall (r = 0.70; 95% CI: 0.67-0.73), supporting construct validity. HUM Tinnitus domain correlated negatively with THI (-0.75; -0.77, -0.73), as expected. Test-retest reliability was excellent (Intraclass Correlation Coefficient [ICC] 0.90, 95% CI: 0.83-0.94). HUM hearing utility was higher for candidates with single-sided deafness (SSD) (0.76) than with traditional and asymmetric hearing loss (0.58, P < .001). Median HUM improved from 0.70 to 0.78 for SSD recipients (P = .002) and 0.57 to 0.75 for traditional recipients (P < .001).

CONCLUSION

HUM is a reliable, valid, and responsive measure of hearing-related health in adults with advanced hearing loss. Unlike traditional instruments such as SSQ and CIQOL, which capture patient-reported outcomes but are not designed for economic analysis, HUM is a preference-based utility instrument that enables cost-effectiveness evaluation. It outperforms the available HUI-3 by better reflecting hearing loss impact and complements existing nonutility instruments used in clinical and health policy decision-making.

Для цитирования: Dixon Peter R, Shah Anuja H, McRackan Theodore R, Feeny David, Cushing Sharon L, Tomlinson George, Chen Joseph M. Validation of the Hearing Utility Measure (HUM) in Cochlear Implant Candidates and Users.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2025. DOI: 10.1002/ohn.70033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.