[Macular image changes of optical coherence tomography after phacoemulsification].

Cheng Bing, Liu Yizhi, Liu Xing, Ge Jian, Ling Yunlan, Zheng Xiaoping

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the effects of phacoemulsification on the macula following uncomplicated phacoemulsification by optical coherence tomography (OCT).

METHODS

Eighty eyes of the senile cataract were chosen randomly. The uncomplicated phacoemulsification was performed. OCT was examined preoperatively and 1 week after the surgery. Preoperative visual acuity, the retinal thickness and phaco power were compared with those after surgery.

RESULTS

In 80 eyes, the preoperative mean foveal thickness was (142.9 +/- 16.7) micrometer and the postoperative (157.9 +/- 36.7) micrometer, the difference being not significant (P > 0.05). Three eyes had macular edema 1 week after surgery. In 11 eyes with Tyndall sign (+ +), the mean postoperative foveal thickness was thicker than the mean preoperative value (P < 0.05). In lower phaco power group, the mean postoperative foveal thickness was (156.2 +/- 18.3) micrometer and the higher phaco power group was (172.6 +/- 32.9) microm (P < 0.05). The best corrected visual acuity after surgery had a negative correlation with the retinal thickness.

CONCLUSIONS

The retinal thickening and macular edema can be found after uncomplicated phacoemulsification. The higher phaco power results in significant inflammation and thicker retina. The visual consequences were proportional to the degrees of macular thickening.

Для цитирования: Cheng Bing, Liu Yizhi, Liu Xing, Ge Jian, Ling Yunlan, Zheng Xiaoping. [Macular image changes of optical coherence tomography after phacoemulsification].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.