DOI 10.1097/mao.0000000000004410
Quality of Information Provided by Artificial Intelligence Chatbots Surrounding the Management of Vestibular Schwannomas: A Comparative Analysis Between ChatGPT-4 and Claude 2.
Аннотация
OBJECTIVE
To examine the quality of information provided by artificial intelligence platforms ChatGPT-4 and Claude 2 surrounding the management of vestibular schwannomas.
STUDY
DESIGN
Cross-sectional.
SETTING
Skull base surgeons were involved from different centers and countries.
INTERVENTION: Thirty-six questions regarding vestibular schwannoma management were tested. Artificial intelligence responses were subsequently evaluated by 19 lateral skull base surgeons using the Quality Assessment of Medical Artificial Intelligence (QAMAI) questionnaire, assessing "Accuracy," "Clarity," "Relevance," "Completeness," "Sources," and "Usefulness."
MAIN OUTCOME MEASURE: The scores of the answers from both chatbots were collected and analyzed using the Student t test. Analysis of responses grouped by stakeholders was performed with McNemar test. Stuart-Maxwell test was used to compare reading level among chatbots. Intraclass correlation coefficient was calculated.
RESULTS
ChatGPT-4 demonstrated significantly improved quality over Claude 2 in 14 of 36 (38.9%) questions, whereas higher-quality scores for Claude 2 were only observed in 2 (5.6%) answers. Chatbots exhibited variation across the dimensions of "Accuracy," "Clarity," "Completeness," "Relevance," and "Usefulness," with ChatGPT-4 demonstrating a statistically significant superior performance. However, no statistically significant difference was found in the assessment of "Sources." Additionally, ChatGPT-4 provided information at a significant lower reading grade level.
CONCLUSIONS
Artificial intelligence platforms failed to consistently provide accurate information surrounding the management of vestibular schwannoma, although ChatGPT-4 achieved significantly higher scores in most analyzed parameters. These findings demonstrate the potential for significant misinformation for patients seeking information through these platforms.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.