MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/hae.70203

Медицинская библиотека · Haemophilia : the official journal of the World Federation of Hemophilia · 2026

Investigation of the Suitability of the ROTEM Assay to Measure Coagulation Potential in Blood From Patients on Concizumab Prophylaxis.

Eichler Hermann, Butta Nora V, Riddell Anne, Augustsson Cecilia, Kjalke Marianne, Jensen Kasper, Paramo-Florencio Andrea, Astermark Jan, Chowdary Pratima, Jiménez-Yuste Victor

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Rotational thromboelastometry (ROTEM) aims to measure the coagulation potential in whole blood. Concizumab, an anti-tissue factor pathway inhibitor (TFPI) antibody for prophylaxis in haemophilia, enhances tissue factor (TF)-initiated coagulation by preventing inhibition of activated factor X (FXa), thus increasing thrombin generation.

OBJECTIVES

To evaluate a modified ROTEM assay for monitoring patients on concizumab prophylaxis.

METHODS

The TF reagent (r_exTEM) was diluted 50,000-fold to make the ROTEM assay sensitive to haemophilia and to concizumab. The effect of concizumab was evaluated in the modified ROTEM in haemophilia A (HA)-like blood (normal blood with added anti-FVIII antibody). ROTEM analysis was performed in blood from patients participating in the explorer7/8 trials during 24 weeks of concizumab prophylaxis. Rotrol N plasma was used as quality control.

RESULTS

In vitro experiments showed concizumab concentration-dependent reduction in clot time (CT) and increase in clot development (α-angle) in HA-like blood. At three of four clinical sites, CT and clot development were stable, variance of the control plasma was ≤12.4% and TF content of the diluted reagent (r_exTEM) was consistent. At these three sites, the correlation between CT versus concizumab exposure, free TFPI and thrombin generation assay parameters was weak (-0.508 to +0.359). Prothrombin time positively correlated with CT (0.523) and negatively correlated with α-angle (-0.659).

CONCLUSION

Due to the poor correlation between ROTEM parameters, concizumab exposure, free TFPI and thrombin generation parameters and the lack of consistent and reliable performance of the modified ROTEM assay, it cannot be recommended for general monitoring of patients on concizumab prophylaxis.

Для цитирования: Eichler Hermann, Butta Nora V, Riddell Anne, Augustsson Cecilia, Kjalke Marianne, Jensen Kasper, Paramo-Florencio Andrea, Astermark Jan, Chowdary Pratima, Jiménez-Yuste Victor. Investigation of the Suitability of the ROTEM Assay to Measure Coagulation Potential in Blood From Patients on Concizumab Prophylaxis.. Haemophilia : the official journal of the World Federation of Hemophilia. 2026. DOI: 10.1111/hae.70203.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.