m+Medelevator.RU
← Поиск публикаций
Journal of refractive surgery (Thorofare, N.J. : 1995) · 2024

Visual Outcomes and Patient Satisfaction After Bilateral Refractive Lens Exchange With a Trifocal Intraocular Lens in 5,226 Patients With Presbyopia.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Llovet-Rausell Andrea, Ortega-Usobiaga Julio, Albarrán-Diego César, Beltrán-Sanz Jaime, Bilbao-Calabuig Rafael, Llovet-Osuna Fernando

Аннотация

PURPOSE: To assess visual and refractive outcomes and visual function after bilateral RayOne Trifocal toric and nontoric intraocular lens (IOL) (Rayner) implantation in patients with presbyopia.

METHODS: Charts of patients with presbyopia who underwent refractive lens exchange with bilateral implantation of the RayOne Trifocal IOL (toric and non-toric) were retrospectively reviewed. Visual and refractive outcomes were evaluated at 3 months. Patient satisfaction, spectacle independence, and visual disturbance profile were assessed by questionnaires.

RESULTS: A total of 5,226 patients were assigned to one of two groups: 1,010 patients had toric IOL implantation (toric group) and 4,216 patients received the non-toric model (non-toric group). Mean ± standard deviation visual acuity at 3 months for the toric group was binocular uncorrected distance visual acuity (UDVA) of 0.07 ± 0.11 logMAR, monocular corrected distance visual acuity (CDVA) of 0.05 ± 0.07 logMAR, binocular uncorrected near visual acuity (UNVA) at 40 cm of 0.10 ± 0.09 logMAR, binocular uncorrected intermediate visual acuity (UIVA) at 40 cm of 0.13 ± 0.12 logMAR, postoperative spherical equivalent (SE) of -0.21 ± 0.47 diopters (D), and cylinder of -0.34 ± 0.40 D. The non-toric group had binocular UDVA of 0.04 ± 0.08 logMAR, monocular CDVA of 0.05 ± 0.07 logMAR, binocular UNVA of 0.10 ± 0.08 logMAR, binocular UIVA of 0.13 ± 0.11 logMAR, SE of -0.08 ± 0.38 D, and cylinder of -0.28 ± 0.34 D. No statistically significant differences were found in achieving spectacle independence and there were high levels of satisfaction in both groups.

CONCLUSIONS: In this retrospective analysis with more than 5,000 patients, both the toric and non-toric RayOne Trifocal IOL models provided good visual performance at all distances, resulting in excellent levels of spectacle independence and patient satisfaction. [J Refract Surg. 2024;40(7):e468-e479.].

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты