[First experience of implantation of extended depth of focus intraocular lenses in patients with glaucoma].
Аннотация на английскомСтатьяНазвание и аннотация: Оригинал на русском
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gorbunova N Yu, Yakovlev R A, Pozdeyeva N A, Mikhailov N O
Аннотация
PURPOSE: This study evaluates the effectiveness of implantation of extended depth of focus (EDOF) intraocular lenses (IOL) in patients with cataract and glaucoma.
MATERIAL AND METHODS: The study included 13 patients (16 eyes) who underwent implantation of the Lentis Comfort EDOF IOL (Teleon Surgical BV, Netherlands). Standard phacoemulsification cataract surgery with IOL implantation was performed in a planned manner after the hypotensive surgery stage in two eyes; a combined procedure was performed in 14 cases. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), near visual acuity, and intraocular pressure (IOP) measured with a Maklakov tonometer were assessed preoperatively, on the first day, and 3-6 months after surgery. Computer perimetry using the 30-2 program and spatial contrast sensitivity (SCS) assessment were also performed preoperatively and at the same follow-up time points.
RESULTS: On the first day after surgery, UCVA was 0.53±0.65, BCVA was 0.85±0.45. Near UCVA (at 40 cm) was 0.5±0.14 on the first day after surgery and 0.56±0.18 at 3-6 months. According to computer perimetry data, retinal light sensitivity values increased in all patients in the long-term (-3.1±2.9 dB). SCS values increased for objects of all sizes compared to preoperative values.
CONCLUSION: Implantation of EDOF IOL contributes to improved vision without reducing contrast sensitivity and retinal light sensitivity in patients with concomitant cataract and glaucoma.
MATERIAL AND METHODS: The study included 13 patients (16 eyes) who underwent implantation of the Lentis Comfort EDOF IOL (Teleon Surgical BV, Netherlands). Standard phacoemulsification cataract surgery with IOL implantation was performed in a planned manner after the hypotensive surgery stage in two eyes; a combined procedure was performed in 14 cases. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), near visual acuity, and intraocular pressure (IOP) measured with a Maklakov tonometer were assessed preoperatively, on the first day, and 3-6 months after surgery. Computer perimetry using the 30-2 program and spatial contrast sensitivity (SCS) assessment were also performed preoperatively and at the same follow-up time points.
RESULTS: On the first day after surgery, UCVA was 0.53±0.65, BCVA was 0.85±0.45. Near UCVA (at 40 cm) was 0.5±0.14 on the first day after surgery and 0.56±0.18 at 3-6 months. According to computer perimetry data, retinal light sensitivity values increased in all patients in the long-term (-3.1±2.9 dB). SCS values increased for objects of all sizes compared to preoperative values.
CONCLUSION: Implantation of EDOF IOL contributes to improved vision without reducing contrast sensitivity and retinal light sensitivity in patients with concomitant cataract and glaucoma.