MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm13103011

Медицинская библиотека · Journal of clinical medicine · 2024

Outcomes of Corneal Compound Myopic Astigmatism with Presbyopia by Zeiss PRESBYOND® Laser Blended Vision LASIK Using Default CRS-Master® Target Refractions for Reduced Anisometropia.

Hernández-Lucena Julia, Alonso-Aliste Federico, Amián-Cordero Jonatan, Sánchez-González José-María

СтатьяПеревод пока не подготовлен

Аннотация

Background/

Objectives

Presbyopia, a common age-related refractive error, affects over a billion people globally and significantly impacts daily life.

Methods

This retrospective study analyzed 288 eyes of 144 patients undergoing LBV PRESBYOND® treatment for myopic presbyopia with astigmatism, aiming to evaluate precision, efficacy, safety, and stability over six months.

Results

Key findings include high efficacy, with 99% of distance-eyes achieving uncorrected distance visual acuity (UDVA) of 20/25 or better, and 85% of near-eyes achieving UDVA of 20/32 or better. The results show excellent refractive outcomes, with 99% of long-sighted eyes and 97% of near-sighted eyes having a postoperative spherical equivalent within ±1.00 D. Safety was demonstrated by no loss of two or more Snellen lines after treatment, with 94% of patients maintaining corrected distance visual acuity (CDVA) before and after surgery.

Conclusions

Overall, LBV PRESBYOND® proved effective, safe, and well tolerated for myopic presbyopia correction, offering satisfactory visual outcomes and potential spectacle independence for various distances. This study underscores the importance of individualized treatment based on patient age, highlighting the positive impact of binocular summation on visual function. This study contributes to the growing body of evidence supporting LBV PRESBYOND® as a viable option for addressing presbyopic myopia, offering insights into its efficacy and safety profile. Further research could explore postoperative stereopsis and long-term outcomes to enhance understanding and refine treatment protocols.

Для цитирования: Hernández-Lucena Julia, Alonso-Aliste Federico, Amián-Cordero Jonatan, Sánchez-González José-María. Outcomes of Corneal Compound Myopic Astigmatism with Presbyopia by Zeiss PRESBYOND® Laser Blended Vision LASIK Using Default CRS-Master® Target Refractions for Reduced Anisometropia.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13103011.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.