MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-55918-5

Медицинская библиотека · Scientific reports · 2024

Efficacy of a new refractive multifocal contact lens for presbyopia.

Kim Do Young, Ahn Hyunmin, Lee Sukyung, Jun Ikhyun, Seo Kyoung Yul, Kim Sang Yeop, Kim Tae-Im

СтатьяПеревод пока не подготовлен

Аннотация

This prospective single-arm study aimed to evaluate the clinical efficacy and safety of a refractive multifocal contact lens for the correction of presbyopia in 22 patients. The participants underwent clinical examinations before and 1 week after wearing a refractive multifocal contact lens (OptaCon ZOOM). The primary endpoints were the corrected distance visual acuity (CDVA) and distance-corrected near visual acuity (DCNVA). Defocus curve, contrast sensitivity, and ocular surface disease index (OSDI) were analyzed. A slit-lamp examination was performed for safety analysis. Contact lens comfort and patient satisfaction were assessed using a questionnaire. No significant difference in CDVA was observed before and 1 week after refractive multifocal contact lens use (p = 0.127), whereas DCNVA was significantly improved after 1 week (p < 0.001). The contrast sensitivity was not significantly affected at any spatial frequency under mesopic or photopic conditions. OSDI was significantly increased (p = 0.023). The patient-reported satisfaction scores were 96.2, 91.9, and 85.0 out of 100 at far, intermediate, and near distances, respectively. No significant adverse events were observed. Refractive multifocal contact lenses improved near vision while maintaining distance vision in presbyopic patients, without compromising contrast sensitivity. The study results suggest that OptaCon ZOOM can be considered safe and effective for the correction of presbyopia.

Для цитирования: Kim Do Young, Ahn Hyunmin, Lee Sukyung, Jun Ikhyun, Seo Kyoung Yul, Kim Sang Yeop, Kim Tae-Im. Efficacy of a new refractive multifocal contact lens for presbyopia.. Scientific reports. 2024. DOI: 10.1038/s41598-024-55918-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.