MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001374

Медицинская библиотека · Journal of cataract and refractive surgery · 2024

Comparison of visual outcomes of bilateral dual-technology diffractive intraocular lens vs blended enhanced monofocal with dual-technology intraocular lens.

Hida Wilson Takashi, Moscovici Bernardo Kaplan, Cortez Cesar Martins, Colombo-Barboza Guilherme Novoa, Tzelikis Patrick Frensel de Moraes, Motta Antonio Francisco Pimenta, De Medeiros Andre Lins, Nose Walton, Carricondo Pedro Carlos

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare clinical outcomes after implantation of TECNIS Synergy (ZFR00V) intraocular lenses (IOLs) in both eyes and implantation of the TECNIS Synergy and TECNIS Eyhance (ICB00) combination in patients undergoing cataract surgery.

SETTING

Department of Cataract, Hospital Oftalmológico de Brasilia (HOB), Brasília, Brazil.

DESIGN

Prospective, interventional, randomized, parallel-group study.

METHODS

Patients were categorized into 2 groups: Group 1: ZFR00V IOL was implanted in both eyes. Group 2: An ICB00 IOL was implanted in the dominant eye, and a ZFR00V IOL was implanted in the nondominant eye.

RESULTS

Visual acuity was similar between the 2 groups (95% CI <0.1 logMAR). A superior visual acuity of ≥ 20/25 (at -2.00 to -2.50 diopters [D]) was achieved in Group 1 (bilateral ZFR00V) than in Group 2 (combination of ZFR00V/ICB00). The binocular defocus curve demonstrated better visual acuity at 40 cm (-2.00 D) and 50 cm (-2.50 D) in Group 1 than in Group 2 ( P < .05). Similar contrast sensitivity values were observed between the 2 groups. Patients in Group 1 reported higher satisfaction (completely satisfied) than those in Group 2 ( P < .05). However, halos and glare were more pronounced in Group 1 than in Group 2 ( P < .05).

CONCLUSIONS

Both presbyopia-correcting IOL combinations showed similar binocular visual acuity results. Group 1 demonstrated enhanced visual acuity in the defocus curve at 40 cm (-2.00 D) and 50 cm (-2.50 D). Comparable contrast sensitivity outcomes were observed in both groups. Patients were more completely satisfied in Group 1 than in Group 2, despite the higher frequency of postoperative nighttime halos and glare.

Для цитирования: Hida Wilson Takashi, Moscovici Bernardo Kaplan, Cortez Cesar Martins, Colombo-Barboza Guilherme Novoa, Tzelikis Patrick Frensel de Moraes, Motta Antonio Francisco Pimenta, De Medeiros Andre Lins, Nose Walton, Carricondo Pedro Carlos. Comparison of visual outcomes of bilateral dual-technology diffractive intraocular lens vs blended enhanced monofocal with dual-technology intraocular lens.. Journal of cataract and refractive surgery. 2024. DOI: 10.1097/j.jcrs.0000000000001374.