Clinical Evaluation of Reading Performance in Refractive Lens Exchange With a Diffractive Continuous-Range-of-Vision Intraocular Lens.

Baur Isabella D, Auffarth Gerd U, Łabuz Grzegorz, Stengele Annette, Hallak Mustafa K, Khoramnia Ramin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Evaluation of reading performance with a novel presbyopia correcting intraocular lens (IOL) in refractive lens exchange using an electronic reading desk.

DESIGN

Prospective interventional before-and-after clinical study.

METHODS

In total, 56 eyes of 28 patients were included. Bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Surgical Vision) during a bilateral delayed sequential refractive lens exchange procedure. Uncorrected and distance corrected reading acuity, reading distance, reading speed, and the smallest print size that could be read effectively at a set (40 cm/80 cm) and subjectively chosen near and intermediate distance were assessed using the Salzburg Reading Desk preoperatively and 6 months after surgery.

RESULTS

Uncorrected near reading acuity increased from 0.61 ± 0.16 logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.05 ± 0.09 logMAR postoperatively at the set near distance (40 cm) and from 0.60 ± 0.11 logMAR to 0.07 ± 0.08 logMAR at the subjectively preferred distance (39.6 ± 5.3 cm and 37.7 ± 4.3 cm). Uncorrected intermediate reading acuity was 0.39 ± 0.19 logMAR preoperatively and 0.08 ± 0.07 logMAR postoperatively at the set intermediate distance (80 cm) and 0.43 ± 0.21 logMAR preoperatively and 0.07 ± 0.08 logMAR postoperatively at the preferred intermediate distance (73.5 ± 9.5 cm and 73.3 ± 5.9 cm).

CONCLUSIONS

Uncorrected intermediate and near reading function considerably improved after bilateral implantation of the TECNIS Synergy IOL. Patients preferred a closer near and intermediate distance to the set distances. However, reading function was comparable for the set and subjectively preferred distances.

Для цитирования: Baur Isabella D, Auffarth Gerd U, Łabuz Grzegorz, Stengele Annette, Hallak Mustafa K, Khoramnia Ramin. Clinical Evaluation of Reading Performance in Refractive Lens Exchange With a Diffractive Continuous-Range-of-Vision Intraocular Lens.. American journal of ophthalmology. 2023. DOI: 10.1016/j.ajo.2023.01.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.