MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20220323-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2022

Visual and Refractive Outcomes Following Laser Blended Vision With Non-linear Aspheric Micro-anisometropia (PRESBYOND) in Myopic and Hyperopic Patients.

Russo Andrea, Reinstein Dan Z, Filini Ottavia, Archer Timothy J, Boldini Alessandro, Cardin Gloria, Festa Giulia, Morescalchi Francesco, Salvalai Chiara, Semeraro Francesco

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report 6-month visual and refractive outcomes following PRESBYOND Laser Blended Vision (Carl Zeiss Meditec) treatment using non-linear aspheric micro-anisometropia laser in situ keratomileusis (LASIK) for the correction of myopic and hyperopic presbyopia.

METHODS

A retrospective, non-comparative study of 139 consecutive patients with a mean age of 53.13 ± 5.84 years (range: 42 to 70 years) treated with LASIK-induced micro-anisometropia using the MEL 90 excimer laser and VisuMax femtosecond laser (both Carl Zeiss Meditec). The target refraction was plano for distance eyes (dominant eye) and between -0.50 and -1.50 diopters (D) for near eyes. Patients were observed for 6 months.

RESULTS

A total of 278 eyes (78 myopic and 200 hyperopic) from 139 patients completed the study. Mean preoperative spherical equivalent (SE) was -3.40 ± 1.83 D (range: -0.50 to -8.25 D) for myopic eyes and +1.61 ± 0.98 D (range: -1.25 to +4.63 D) for hyperopic eyes. Mean postoperative SE refraction of distance eyes was +0.20 ± 0.35 D (range: -0.38 to +1.00 D) and -0.14 ± 0.42 D (range: -1.38 to +0.88 D) for myopic and hyperopic eyes, respectively. Mean postoperative SE refraction of near eyes was -0.90 ± 0.44 D (range: -0.13 to -2.25 D) and -1.21 ± 0.48 D (range: -0.13 to -2.25 D) for myopic and hyperopic eyes, respectively. Mean binocular uncorrected near visual acuity was 0.70 ± 0.28 logMAR (range: 0.32 to 1.00 logMAR) and 0.79 ± 0.27 logMAR (range: 0.25 to 1.00 logMAR) for myopic and hyperopic eyes, respectively. Mean binocular uncorrected distance visual acuity was 1.19 ± 0.18 logMAR (range: 0.63 to 1.25 logMAR) and 1.14 ± 0.26 logMAR (range: 0.40 to 1.25 logMAR) for myopic and hyperopic eyes, respectively. Stereoacuity was better than 100 seconds of arc in 79% of myopic eyes and 85% of hyperopic eyes and all vision quality scores were greater than 90 of 100. No eyes lost two or more lines.

CONCLUSIONS

The non-linear aspheric micro-anisometropia protocol resulted in safe and effective visual outcomes in patients with both myopic and hyperopic presbyopia. [J Refract Surg. 2022;38(5):288-297.].

Для цитирования: Russo Andrea, Reinstein Dan Z, Filini Ottavia, Archer Timothy J, Boldini Alessandro, Cardin Gloria, Festa Giulia, Morescalchi Francesco, Salvalai Chiara, Semeraro Francesco. Visual and Refractive Outcomes Following Laser Blended Vision With Non-linear Aspheric Micro-anisometropia (PRESBYOND) in Myopic and Hyperopic Patients.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2022. DOI: 10.3928/1081597x-20220323-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.