MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.07-0619

Медицинская библиотека · Chest · 2007

Mixed-expired and end-tidal CO2 distinguish between ventilation and perfusion defects during exercise testing in patients with lung and heart diseases.

Hansen James E, Ulubay Gaye, Chow Bing Fai, Sun Xing-Guo, Wasserman Karlman

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Mismatching of ventilation to perfusion is found in patients with COPD, left ventricular failure (LVF), and pulmonary vascular diseases. Such mismatching may be due to ventilation or perfusion defects or both. Our primary hypothesis was that pressures of mixed-expired CO2 pressure (Peco(2)), end-tidal Pco(2) pressure (Petco(2)), and their ratios would differ between groups during exercise testing, depending on whether the ventilation/perfusion (V/Q) abnormality was dominantly caused by airways or perfusion defects.

METHODS

We administered incremental cycle ergometry tests to 25 normal subjects and three groups of 25 patients, each group with uncomplicated COPD, LVF, or primary pulmonary arterial hypertension (PAH). We compared Peco(2), Petco(2), and their ratios at rest, unloaded pedaling, anaerobic threshold, and peak exercise.

RESULTS

Although each patient group had mean peak O(2) uptake of approximately 50% of predicted normal, the levels and patterns of change for each group for Peco(2), Petco(2), and their ratios were surprisingly distinctive. As hypothesized, the COPD group always had markedly lower Peco(2)/Petco(2) ratios than all other groups (p < 0.001). In addition, patients with LVF had slightly lower Peco(2)/Petco(2) ratios at heavy exercise than normal subjects (p < 0.05). At all times, except for COPD group Petco(2) at peak exercise, each group had significantly lower Petco(2) and Peco(2) than normal subjects (p < 0.001). In patients with PAH, the Petco(2) decline with exercise was distinctive.

CONCLUSIONS

The levels and changes in Peco(2), Petco(2), and their ratios during cardiopulmonary exercise testing are distinctive and explained by the differing pathophysiologies of V/Q mismatching in these disorders.

Для цитирования: Hansen James E, Ulubay Gaye, Chow Bing Fai, Sun Xing-Guo, Wasserman Karlman. Mixed-expired and end-tidal CO2 distinguish between ventilation and perfusion defects during exercise testing in patients with lung and heart diseases.. Chest. 2007. DOI: 10.1378/chest.07-0619.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.