MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otohns.2009.03.028

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2009

Failures in stapedotomy for otosclerosis.

Babighian Gregorio G, Albu Silviu

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To review the results of 78 revision stapedotomies, determining the causes of failure and the predictors of surgical success.

STUDY

DESIGN

Case series with chart review.

SETTING

Tertiary referral center.

SUBJECTS AND

METHODS

Seventy-eight operations were performed in a tertiary referral center on 72 patients between 1995 and 2005. Indication for surgery was recurrent or persistent conductive hearing loss.

RESULTS

The most common causes of failure were prosthesis displacement, incus necrosis, and oval window fibrosis. Postoperative air-bone gap was closed to within 10 dB in 54 percent of cases, and mean postoperative air-bone gap was 13.6 dB. Overclosure occurred in five percent of cases, sensorineural hearing loss in six percent of cases, and we had one postoperative dead ear. Success rates were higher in cases presenting prosthesis or ossicular malfunction than in cases with oval window problems. Hearing results did not differ if the prosthesis was crimped to either the malleus or the remnant of the long incudal process. Outcomes were similar for local or general anesthesia, and the nitinol piston did not significantly improve the hearing results.

CONCLUSION

Revision stapedotomy is less successful than primary procedure. Lessening the surgical trauma provides the most favorable results.

Для цитирования: Babighian Gregorio G, Albu Silviu. Failures in stapedotomy for otosclerosis.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2009. DOI: 10.1016/j.otohns.2009.03.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.