DOI 10.1097/j.jcrs.0000000000000590
Contamination of multiuse eyedrop bottles by exhaled air from patients wearing face masks during the COVID-19 pandemic: Schlieren imaging analysis.
Аннотация
PURPOSE: To determine whether mask-induced redirected exhaled air through the superior mask gap contacts multiuse eyedrop bottles during drop administration and the efficacy of interventions to reduce such exposure.
SETTING
Academic ophthalmology center.
DESIGN
Interventional analysis.
METHODS
Schlieren airflow imaging was taken of an examinee wearing frequently used face masks and enacting common clinical scenarios-with and without manual occlusion of the superior mask gap and/or neck extension-and maximum visible vertical breath plume height was quantified. Bottle height during eyedrop administration was measured for 4 ophthalmologists during instillation to 8 eyes of 4 subjects.
RESULTS
Breath plume height (mean ± SD 275.5 ± 16.3 mm) was significantly greater than mean bottle height (13.9 ± 4.7 mm; P < .01). Plume height was reduced with manual mask occlusion vs without (P < .01) and was also lower than mean bottle height with manual mask occlusion (P < .01) but not in the absence of occlusion (P < .01). Neck extension alone did not adequately redirect liberated breath to prevent contact with a bottle.
CONCLUSIONS
Exhaled air liberated from commonly worn patient face masks was able to contact multiuse eyedrop bottles during eyedrop administration. These findings have important patient safety implications during the coronavirus disease 2019 pandemic and with other respiratory pathogens because these multiuse bottles could potentially serve as vectors of disease. Occlusion of the superior mask gap significantly reduces breath contamination and should be strongly considered by eyecare providers during drop administration in eye clinics.