DOI 10.1038/s41433-021-01551-9
Outcomes of the Haigis-L formula for calculating intraocular lens power in extreme long axis eyes after myopic laser in situ keratomileusis.
Аннотация
PURPOSE: To evaluate the accuracy of refractive prediction by the Haigis-L formula compared to four other IOL power calculation formulas in eyes with extremely long axial lengths (AL > 29.0 mm) after LASIK.
SETTING
Shanghai Eye Disease and Prevention Treatment Center, Shanghai, China.
DESIGN
Retrospective case series.
METHODS
Twenty-nine eyes from 19 patients were available for analysis. The primary outcome measure was the arithmetic refractive prediction error (RPE), defined as the difference between the actual postoperative refractive error and the intended formula-derived refractive target. The main outcome measure was the median absolute refraction prediction error (MedAE). The accuracy of the Haigis-L was compared with Barrett True K No History, Shammas-PL, SRK/Tcorrected K, and Holladay 2corrected K methods to calculate IOL power.
RESULTS
The Haigis-L formula had a significantly larger MedAE than Shammas-PL and SRK/Tcorrected K formulas (P = 0.005 and P = 0.015, respectively), a smaller percentage of eyes within ±1.50 diopter (D) of predicted error in refraction compared with Shammas-PL and SRK/Tcorrected K formulas (P = 0.014 and P = 0.005, respectively). The refractive prediction errors of 6 eyes with corneal keratometry of less than 35 D by Haigis-L all had more than 1.95 D of myopic overestimation, while none of the other four methods resulted in an absolute error over 1.95 D.
CONCLUSIONS
The Haigis-L formula was relatively accurate in predicting extreme long axis (>29.0 mm) eyes after myopic LASIK surgery but less accurate for eyes with extremely flat corneas (<35 D). SRK/Tcorrected K and Shammas-PL performed better than the other methods for refractive prediction in this type of eyes.
SYNOPSIS: Haigis-L performed worse than SRK/Tcorrected K and Shammas-PL in predicting IOL power in extremely long axis (>29.0 mm) eyes after myopic LASIK, especially with extremely flat corneas (K < 35 D).