MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.str.26.11.2053

Медицинская библиотека · Stroke · 1995

Can transcranial Doppler really detect reduced cerebral perfusion states?

Sugimori H, Ibayashi S, Fujii K, Sadoshima S, Kuwabara Y, Fujishima M

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: This study was designed to determine whether transcranial Doppler ultrasonography (TCD) may detect reduced perfusion states of the brain in patients with hypertension or diabetes mellitus with suspected cerebral atherosclerosis and arteriolosclerosis.

METHODS

We determined blood flow velocity with TCD in the middle cerebral artery and cerebrovascular vasodilator responses to carbon dioxide in 22 patients with or without carotid artery occlusive disease and minor stroke; we compared the results with the measurements of cerebral blood flow and oxygen metabolism by positron emission tomography (PET).

RESULTS

Blood flow velocity measured by TCD correlated with ipsilateral cerebral blood flow measured by PET in frontal, temporal, and striatal regions and throughout the entire hemisphere (P < .05 to P < .005). Relative changes in blood flow velocity and calculated cerebrovascular resistance tested by carbon dioxide inhalation both correlated closely with regional mean transit time (calculated as the ratio of cerebral blood volume divided by cerebral blood flow) in frontal, striatal, temporal, parietal, and occipital regions and also in the entire hemisphere (P < .05 to P < .0001). TCD variables did not correlate with hemispheric measurements of oxygen metabolism by PET.

CONCLUSIONS

Although TCD is not useful in assessing impairments of cerebral metabolism, it is useful for detecting abnormalities of cerebral hemodynamics among patients with risk factors for cerebrovascular disease.

Для цитирования: Sugimori H, Ibayashi S, Fujii K, Sadoshima S, Kuwabara Y, Fujishima M. Can transcranial Doppler really detect reduced cerebral perfusion states?. Stroke. 1995. DOI: 10.1161/01.str.26.11.2053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.