m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2005

Anterior chamber and sutured posterior chamber intraocular lenses in eyes with poor capsular support.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Donaldson Kendall E, Gorscak Jason J, Budenz Donald L, Feuer William J, Benz Matthew S, Forster Richard K

Аннотация

PURPOSE: To compare the clinical outcomes and complications of patients who had surgical placement of anterior chamber (AC IOLs) and sutured posterior chamber intraocular lenses (PC IOLs) after cataract surgery resulting in poor capsular support.

SETTING: Department of Ophthalmology, Bascom Palmer Eye Institute, Miami, Florida.

METHODS: A retrospective interventional comparative case series of 181 eyes of 181 patients that had implantation of an intraocular lens with inadequate capsular support was conducted. A chart review of all patients that had implantation of AC IOLs or sutured PC IOLs at a tertiary care eye hospital between 1995 and 2001 was conducted.

RESULTS: Outcome measures included final best-corrected visual acuity, spherical equivalent, and postoperative complications (pseudophakic bullous keratopathy, elevated intraocular pressure [IOP] inflammation, retinal detachment, suture erosion, cystoid macular edema). Of 702 charts reviewed, 181 were found to fit inclusion and exclusion criteria. The postoperative complication risk ratio was 0.80 (95% confidence interval [CI]: 0.52-1.23) for AC IOLs compared with PC IOLs. The most common complication experienced by patients having implantation of either lens type was elevated IOP (AC IOL: 38%; PC IOL: 42%). The incidence of other complications was similar between the groups. Best-corrected visual acuity was similar; however, final spherical equivalent trended toward more myopic values in the PC IOL group (-0.82 +/- 1.67 for AC IOL versus -1.32 +/- 2.12 for PC IOL).

CONCLUSIONS: The findings suggest that no significant differences in outcome exist when comparing AC IOLs to sutured PC IOLs in complicated cataract extraction with poor capsular support. Recent advances in AC IOL design have yielded lenses that provide a safe, effective alternative to sutured PC IOLs.