MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2459/jcm.0b013e32832720a0

Медицинская библиотека · Journal of cardiovascular medicine (Hagerstown, Md.) · 2009

Unexpected long durability of a low-profile porcine Liotta bioprosthesis in mitral position.

Campanella Antonio, Comoglio Chiara, Sansone Fabrizio, Rinaldi Mauro

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

We report a case in which replacement of a low-profile porcine Liotta bioprosthesis was required 21 years after initial implantation. The patient underwent mitral valve replacement with a 28-mm Liotta bioprosthesis in 1985 for mitral stenosis. Twenty-one years later, severe mitral regurgitation was detected at echocardiography and mitral valve reoperation combined with tricuspid annuloplasty was successfully performed. Focal perforation of two cusps with consequent intravalvular leak on bioprosthesis was found. This is the longest durability report for a Liotta bioprosthesis in mitral position.

Для цитирования: Campanella Antonio, Comoglio Chiara, Sansone Fabrizio, Rinaldi Mauro. Unexpected long durability of a low-profile porcine Liotta bioprosthesis in mitral position.. Journal of cardiovascular medicine (Hagerstown, Md.). 2009. DOI: 10.2459/jcm.0b013e32832720a0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.