MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20240506-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2024

Visual and Refractive Outcomes After Bi-aspheric Trifocal Toric Diffractive Intraocular Lens Implantation.

Tañá-Sanz Pedro, Tañá-Sanz Santiago, Rodríguez-Carrillo María Dolores, Ruiz-Santos María, de Toledo Clara Álvarez, Tañá-Rivero Pedro

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess clinical outcomes after cataract surgery with bilateral implantation of a new bi-aspheric diffractive intraocular lens (IOL).

METHODS

Thirty patients underwent bilateral implantation of the Asqelio Trifocal Toric IOL (AST Products, Inc) and were evaluated 3 months postoperatively. Main outcomes included refractive error, photopic monocular and binocular uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CDIVA) at 60 cm, and near (UNVA, CDNVA) at 40 cm visual acuities. Mesopic monocular and binocular CDNVA were also measured. Defocus curves, binocular contrast sensitivity under photopic and mesopic conditions with and without glare and rotational stability were determined. Patients completed Catquest-9SF and visual symptoms questionnaires.

RESULTS

Average values of binocular photopic CDVA, CDIVA, and CDNVA, and mesopic CDNVA were -0.04 ± 0.06, 0.02 ± 0.08, 0.02 ± 0.07, and 0.22 ± 0.11 logMAR, respectively. All patients achieved cumulative CDVA ⩾ 20/25, and CDIVA and CDNVA of 20/32 or better. Binocular depth of focus was approximately 3.25 diopters (D). Mean postoperative spherical equivalent was -0.08 ± 0.26 D, with 95% of eyes within ±0.50 D. Mean postoperative refractive cylinder was -0.22 ± 0.27 D, with 91.67% of eyes within 0.50 D or less, respectively. IOL rotation averaged 0.25 ± 0.65 degrees, all eyes having rotation of less than 5 degrees. Contrast sensitivity was within or above normal levels under photopic and mesopic conditions, with or without glare, except for 12 cpd under mesopic conditions with glare. Questionnaire responses indicated 96.67% of patients were satisfied or very satisfied with postoperative vision, and 80.00% to 96.67% reported no difficulty in different daily activities.

CONCLUSIONS

The Asqelio Trifocal Toric IOL demonstrated favorable outcomes, providing excellent visual performance at all distances, precise refractive results, and remarkable rotational stability. Patients reported high satisfaction levels and minimal difficulty in daily activities. [J Refract Surg. 2024;40(6):e407-e419.].

Для цитирования: Tañá-Sanz Pedro, Tañá-Sanz Santiago, Rodríguez-Carrillo María Dolores, Ruiz-Santos María, de Toledo Clara Álvarez, Tañá-Rivero Pedro. Visual and Refractive Outcomes After Bi-aspheric Trifocal Toric Diffractive Intraocular Lens Implantation.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2024. DOI: 10.3928/1081597x-20240506-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.