MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-55926-5

Медицинская библиотека · Scientific reports · 2024

Comparison of visual performance between diffractive bifocal and diffractive trifocal intraocular lenses.

Kawamura Junya, Tanabe Hirotaka, Shojo Tomohiro, Yamauchi Tomofusa, Takase Kosuke, Tabuchi Hitoshi

СтатьяПеревод пока не подготовлен

Аннотация

To evaluate the visual performance of a diffractive bifocal intraocular lens (IOL) with + 4.0 D near addition (ZMB00) and a diffractive trifocal IOL with + 2.17 D and + 3.25 D near addition (AcrySof IQ PanOptix TFNT00), we investigated the 10-week postoperative parameters after cataract surgery in which ZMB00 or TFNT00 lenses were implanted bilaterally from 2011 to 2020 (with a 3-month interval between implantation of the right and left lenses). The study included 1448 eyes of 724 patients. The diffractive bifocal group comprised 1326 eyes of 663 patients (aged 67.0 ± 7.8 years; females/males, 518/145), and the diffractive trifocal group comprised 122 eyes of 61 patients (aged 66.6 ± 7.3 years; females/males, 35/26). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter, ensured statistical validity. Uncorrected near visual acuity and higher-order aberrations (ocular/internal, scaled to a pupil size of 4 mm) (Wavefront_4mm_postoperative_Ocular/Internal_Spherical) were significantly better in the bifocal group (p < 0.00068, Wald test). Uncorrected intermediate visual acuity, contrast sensitivity (6.3/4.0/2.5/1.6/1.0/0.7 degrees), and contrast sensitivity with glare (4.0/1.6/1.0/0.7 degrees) were significantly better in the trifocal group (p < 0.00068, Wald test).

Для цитирования: Kawamura Junya, Tanabe Hirotaka, Shojo Tomohiro, Yamauchi Tomofusa, Takase Kosuke, Tabuchi Hitoshi. Comparison of visual performance between diffractive bifocal and diffractive trifocal intraocular lenses.. Scientific reports. 2024. DOI: 10.1038/s41598-024-55926-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.