MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-023-06230-x

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023

Effect of intraocular lens material and haptic design on anterior capsule contraction after cataract surgery: A systematic review and meta-analysis.

Chen Lu, Zhong Yueyang, Yao Ke, Fu Qiuli

МетаанализСистематический обзорСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare anterior capsule contraction (ACC) after cataract surgery with implantation of intraocular lens (IOLs) of different materials and designs.

METHODS

We searched three electronic databases for relevant studies published up to January 1, 2023. Five randomized controlled trails (RCTs) and three cohort studies involving 1,221 eyes were included in quantitative synthesis. We extracted data, assessed their quality independently, and calculated standard mean difference (SMD) using a random-effects model. Six RCTs and one retrospective cohort were included in information summary.

RESULTS

The contraction of the anterior capsule opening area in the hydrophilic group was larger than that of the hydrophobic group from one month to one year postoperatively (P < 0.001 and P < 0.001, respectively). Specifically, the hydrophilic group showed greater contraction of the anterior capsule opening area at one month postoperatively (Standardized mean difference [SMD] = -0.73, 95% confidence interval [CI] = -0.93 to -0.52), three months (SMD = -1.04, 95% CI = -1.32 to -0.75), six months (SMD = -0.99, 95% CI = -1.24 to -0.74) and one year (SMD = -1.33, 95% CI = -2.50 to -0.16). As of one year postoperatively, the anterior capsular opening area showed a trend of decreasing over time in both groups (P = 0.046 and P = 0.050, respectively). In information summary, three studies indicated no relationship between haptic design and ACC, while the other four studies reported that the number and shape of haptic would affect ACC.

CONCLUSION

This meta-analysis suggested that the postoperative ACC after the implantation of hydrophobic IOLs was less than that induced by hydrophilic IOLs. Haptic design may also affect the degree of ACC.

Для цитирования: Chen Lu, Zhong Yueyang, Yao Ke, Fu Qiuli. Effect of intraocular lens material and haptic design on anterior capsule contraction after cataract surgery: A systematic review and meta-analysis.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2023. DOI: 10.1007/s00417-023-06230-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.