MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-20-0305

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2020

Predictors of Long-Term Infections After Cardiac Implantable Electronic Device Surgery - Utility of Novel PADIT and PACE DRAP Scores.

Sławek-Szmyt Sylwia, Araszkiewicz Aleksander, Grygier Marek, Szmyt Krzysztof, Chmielewska-Michalak Lidia, Seniuk Wojciech, Waśniewski Michał, Smukowski Tomasz, Lesiak Maciej, Mitkowski Przemysław

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac implantable electronic device-related infections (CDI) are of increasing importance and involve substantial healthcare resources. This study aimed to evaluate potential CDI risk factors and the utility of the novel PADIT and PACE DRAP scores to predict CDI.

METHODS AND

RESULTS

The study group included 1,000 consecutive patients undergoing implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy (CRT) surgery. Patients' and procedural characteristics were collected. CDI occurrence was assessed during 1-year follow-up. Moreover, if periprocedural significant pocket hematoma (SPH) occurred, the maximal volume was calculated based on ultrasonographic measurements and ABC/2 formula. The overall incidence of CDI was 1.8%. In the multivariable regression analysis independent CDI risk factors were: age >75 years (odds ratio [OR]: 5.93; 95% confidence interval [CI]: 1.77-19.84), system upgrade procedure (OR: 6.46; CI: 1.94-21.44), procedure duration >1 h (OR: 13.96; CI: 4.40-44.25), presence of SPH (OR: 4.95; CI: 1.62-15.13) and reintervention within 1 month (OR: 16.29; CI: 3.14-84.50). The PACE DRAP score had higher discrimination of CDI incidence (area under curve [AUC] 0.72) as compared with the PADIT score (AUC 0.63).

CONCLUSIONS

We identified 5 independent risk factors of CDI development. Our study also showed that the PACE DRAP score was better able to identify patients at high risk of CDI than the PADIT score.

Для цитирования: Sławek-Szmyt Sylwia, Araszkiewicz Aleksander, Grygier Marek, Szmyt Krzysztof, Chmielewska-Michalak Lidia, Seniuk Wojciech, Waśniewski Michał, Smukowski Tomasz, Lesiak Maciej, Mitkowski Przemysław. Predictors of Long-Term Infections After Cardiac Implantable Electronic Device Surgery - Utility of Novel PADIT and PACE DRAP Scores.. Circulation journal : official journal of the Japanese Circulation Society. 2020. DOI: 10.1253/circj.cj-20-0305.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.