MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1902/jop.2010.100115

Медицинская библиотека · Journal of periodontology · 2010

A 4-year evaluation of the peri-implant parameters of immediately loaded implants placed in fresh extraction sockets.

Crespi Roberto, Capparè Paolo, Gherlone Enrico

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The present study considers the correlation between the meaning of keratinized mucosa (KM) and the long-term maintenance of endosseous root-form dental implants placed in fresh sockets and immediately loaded.

METHODS

Twenty-nine patients requiring extractions of ≥2 teeth in the maxilla and mandible were selected. One-hundred thirty-two maxillary and 32 mandibular teeth, in the incisor, canine, and premolar regions, were extracted. Implants were positioned in fresh sockets and immediately loaded. Based on the amounts of KM, implants were categorized as follows: KM ≥2 mm (group A) and KM <2 mm (group B). Clinical parameters (probing depth, modified plaque index, modified bleeding index, and gingival index) and marginal bone levels were followed at 4 years after implant placement. Comparisons between group A and B values were performed by the Student two-tailed t test.

RESULTS

At 4-year follow-up, a survival rate of 100% was reported for all implants. The mean values of group B were significantly higher (P <0.05) than group A for the following parameters: gingival index (group A, 0.67 ± 0.09; group B, 1.01 ± 0.11); modified plaque index (group A, 1.18 ± 0.09; group B, 1.71 ± 0.12); and modified bleeding index (group A, 0.35 ± 0.05; group B, 0.78 ± 0.05). Gingival recession was significantly elevated in group B. In both group A and group B, up to 60% of gingival recession occurred within the first 6 months. For mean bone loss values, statistically non-significant differences were reported between groups.

CONCLUSIONS

At 4-year follow-up, the results suggested that the presence of mid-buccal KM is not a critical factor in the maintenance of interproximal bone level around fresh socket implants immediately loaded. Conversely, less width of KM is significantly associated with more gingival inflammation, more plaque accumulation, and more gingival recession.

Для цитирования: Crespi Roberto, Capparè Paolo, Gherlone Enrico. A 4-year evaluation of the peri-implant parameters of immediately loaded implants placed in fresh extraction sockets.. Journal of periodontology. 2010. DOI: 10.1902/jop.2010.100115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.