PURPOSE: Radiographic parameters of mandibular trabecular bone structure between 67 subjects having hypodontia and those without were studied on digital panoramic radiographs.

MATERIALS AND

METHODS

Three regions of interest (ROI) were defined: the ascending ramus, apical of the mandibular molar and mesial of the first mandibular molar. The effects of the presence of hypodontia and the ROI on the mandibular trabecular bone structure were tested for statistical significance by means of multivariate analysis.

RESULTS

Radiographic parameters of trabecular bone architecture were found to differ between various regions of the mandible (p = 0.000), but not between the group of hypodontia subjects and their controls (p = 0.23). There was no interaction effect between the ROIs and the two groups (p = 0.79). For people having hypodontia, some directional parameters of trabecular bone have a reverse correlation with the number of missing teeth. The fractal dimension and the number and perimeter of white segments in the binarized image correlate positively with the number of congenitally missing teeth.

CONCLUSIONS

A limited number of parameters of radiographic mandibular trabecular bone structure correlate with the number of missing teeth. However, a markable difference in radiographic parameters of mandibular trabecular bone structure between hypodontia and non-hypodontia subjects could not be demonstrated.

Для цитирования: Créton Marijn, Geraets Wil, Verhoeven Jan Willem, van der Stelt Paul F, Verhey Hans, Cune Marco. Radiographic features of mandibular trabecular bone structure in hypodontia.. Clinical implant dentistry and related research. 2009. DOI: 10.1111/j.1708-8208.2009.00246.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.