High-Flow or Standard Oxygen in Acute Hypoxemic Respiratory Failure.

Frat Jean-Pierre, Quenot Jean-Pierre, Guitton Christophe, Coudroy Rémi, Gacouin Arnaud, Badie Julio, Demoule Alexandre, Contou Damien, Carteaux Guillaume, Ehrmann Stephan, Jarousseau Fabien, Sedillot Nicholas, Rigaud Jean-Philippe, Reignier Jean, Beloncle François, Dureau Anne-Florence, Ferré Alexis, Daubin Cédric, Bourreau Anna, Delbove Agathe, Pradel Gaël, Fatah Abdelhamid, Colin Gwenhael, Deniel Guillaume, Lamouret Olivier, La Combe Béatrice, Prat Gwénaël, Galerneau Louis-Marie, Bourdin Gaël, Julien Gautier, Curtiaud Anaïs, Saint-Léger Mélanie, Turbil Emanuele, Reynaud Faustine, Chamblet Louis, Ragot Stéphanie, Thille Arnaud W, SOHO Trial Group and the REVA Network

СтатьяМногоцентровое исследованиеРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Data are needed on the effect of oxygen delivered through a high-flow nasal cannula, as compared with standard oxygen therapy, on intubation and mortality in patients with acute hypoxemic respiratory failure.

METHODS

In this multicenter, open-label trial, we randomly assigned patients who had acute hypoxemic respiratory failure to receive high-flow-oxygen or standard-oxygen therapy. All the patients had a ratio of the partial pressure of arterial oxygen to the fraction of inspired oxygen of 200 or less, a respiratory rate of more than 25 breaths per minute, and pulmonary infiltrate on chest imaging. The primary outcome was death by day 28.

RESULTS

A total of 1116 patients underwent randomization. Of these patients, 1110 (556 in the high-flow-oxygen group and 554 in the standard-oxygen group) were included in the analysis. Mortality at day 28 was 14.6% (in 81 of 556 patients) in the high-flow-oxygen group and 14.6% (in 81 of 554 patients) in the standard-oxygen group (difference, -0.05 percentage points; 95% confidence interval [CI], -4.21 to 4.10; P = 0.98). The incidence of intubation by day 28 was 42.4% (in 236 of 556 patients) in the high-flow-oxygen group and 48.4% (in 268 of 554 patients) in the standard-oxygen group (difference, -5.93 percentage points; 95% CI, -11.78 to -0.08). Serious adverse events (cardiac arrest or pneumothorax) occurred during spontaneous breathing in 13 patients (2.3%) in the high-flow-oxygen group and in 6 patients (1.1%) in the standard-oxygen group.

CONCLUSIONS

Among patients with acute hypoxemic respiratory failure, the use of oxygen delivered through a high-flow nasal cannula did not significantly reduce mortality at day 28. (Funded by the French Ministry of Health and Fisher and Paykel Healthcare; SOHO ClinicalTrials.gov number, NCT04468126.).

Для цитирования: Frat Jean-Pierre, Quenot Jean-Pierre, Guitton Christophe, Coudroy Rémi, Gacouin Arnaud, Badie Julio, Demoule Alexandre, Contou Damien, Carteaux Guillaume, Ehrmann Stephan, Jarousseau Fabien, Sedillot Nicholas, Rigaud Jean-Philippe, Reignier Jean, Beloncle François, Dureau Anne-Florence, Ferré Alexis, Daubin Cédric, Bourreau Anna, Delbove Agathe, Pradel Gaël, Fatah Abdelhamid, Colin Gwenhael, Deniel Guillaume, Lamouret Olivier, La Combe Béatrice, Prat Gwénaël, Galerneau Louis-Marie, Bourdin Gaël, Julien Gautier, Curtiaud Anaïs, Saint-Léger Mélanie, Turbil Emanuele, Reynaud Faustine, Chamblet Louis, Ragot Stéphanie, Thille Arnaud W, SOHO Trial Group and the REVA Network. High-Flow or Standard Oxygen in Acute Hypoxemic Respiratory Failure.. The New England journal of medicine. 2026. DOI: 10.1056/nejmoa2516087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.