Systolic right ventricular function assessment by pulsed wave tissue Doppler imaging of the tricuspid annulus.

Tüller David, Steiner Martin, Wahl Andreas, Kabok Marika, Seiler Christian

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Systolic right ventricular (RV) function is an important predictor in the course of various congenital and acquired heart diseases. So far, tricuspid annular motion velocity in systole as obtained by pulsed wave tissue Doppler imaging (TDI) has rarely been investigated for RV function assessment in a sizeable adult patient population.

METHODS

258 individuals were included in the study. Among them, there were 107 individuals without cardiovascular disease, 71 patients with predominant RV dysfunction, 40 patients with pulmonary artery hypertension, and 40 patients with predominant left ventricular dysfunction. The reference methods for RV systolic function assessment were biplane two-dimensional echocardiography and magnetic resonance imaging (MRI; n = 31) for the calculation of RV ejection fraction (EF). Lateral tricuspid valve annular motion velocities in systole (TVlat, cm/s) were recorded using pulsed wave TDI from the apical 4-chamber view (long axis function).

RESULTS

RV EF as determined by biplane echocardiography correlated significantly with respective values as assessed by MRI: RVEFecho = RV EFMRI + 1.6; r2 = 0.569, p <0.0001. Using the best TVlat threshold of 12 cm/s, distinction between the group with RV dysfunction and the other groups was possible with 86% sensitivity and 83% specificity. There was a direct and significant correlation between TVlat and RV ejection fraction (p <0.0001). Using TVlat thresholds of 12 and 9 cm/s, distinction between normal RV EF (>55%), moderately reduced (30-55%) and severely reduced RV EF (<30%) was possible with 84% sensitivity and 81% specificity, respectively with 83% sensitivity and 67% specificity.

CONCLUSION

Systolic long axis velocity measurement of the lateral tricuspid annulus is useful and accurate to assess RV systolic function in a broad patient population. Thresholds of 12 and 9 cm/s allow differentiation between normal, moderately reduced and severely reduced RV ejection fraction.

Для цитирования: Tüller David, Steiner Martin, Wahl Andreas, Kabok Marika, Seiler Christian. Systolic right ventricular function assessment by pulsed wave tissue Doppler imaging of the tricuspid annulus.. Swiss medical weekly. 2005. DOI: 10.4414/smw.2005.11043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.