MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2004.08.008

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2004

Assessment of the tricuspid valve: a comparison of four transesophageal echocardiographic windows.

Maslow Andrew D, Schwartz Carl, Singh Arun K

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Tricuspid valve annular dilation is associated with persistent tricuspid valve regurgitation (TR) after cardiac surgery. The purpose of this study is to compare assessment of the tricuspid valve annulus from 4 different echocardiographic windows.

DESIGN

Prospective study.

SETTING

Single tertiary care hospital.

PATIENTS: Twenty patients undergoing cardiac surgery, including right atriotomy.

METHODS

Measurements of the tricuspid valve annular diameter during ventricular diastole (TVADd) and of TR jet dimensions, obtained from 3 different transesophageal and 1 transgastric echocardiographic window, were compared with each other and with that measured by the surgeon during cardiopulmonary bypass. Data were compared using correlation statistics, bias analysis, and analysis of variance for repeated measures.

RESULTS

TVAD measured by the surgeon both agreed and correlated best with TVADd measured from the transgastric right ventricular inflow/outflow window (r = 0.98; mean bias 0.04 cm). The proximal TR jet widths and TR jet lengths were larger when measured from midesophageal 4-chamber and midesophageal right ventricular inflow/outflow windows compared with other windows (p < 0.01).

CONCLUSION

TVADd was more accurately measured from transgastric windows, whereas the measurements of the TR jet were greater from esophageal windows. These data support imaging from multiple windows to obtain a more comprehensive assessment of the tricuspid valve anatomy and function.

Для цитирования: Maslow Andrew D, Schwartz Carl, Singh Arun K. Assessment of the tricuspid valve: a comparison of four transesophageal echocardiographic windows.. Journal of cardiothoracic and vascular anesthesia. 2004. DOI: 10.1053/j.jvca.2004.08.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.