DOI 10.3760/cma.j.cn112142-20250421-00192

Медицинская библиотека · [Zhonghua yan ke za zhi] Chinese journal of ophthalmology · 2025

[Safety and efficacy of aspheric phakic IOL implantation in myopia: short-term clinical results].

Wang X Y, Dong Z, Xiong Y, Li Y, Luo Y, Yang Y B, Liu L, Lin D, Wang Z, Xiong L, Zhang G B, Zhang Q S, Zhou X T, Wang N L

СтатьяРандомизированное исследованиеМногоцентровое исследованиеАннотация на английскомПеревод пока не подготовлен

Аннотация

Objective

To evaluate the clinical safety and efficacy of aspheric phakic intraocular lens (PIOL) implantation for myopia correction.

Methods

This prospective, multicenter, single-blind (patient-masked), randomized, controlled clinical trial was conducted from March 2019 to April 2022 across nine ophthalmic centers (including the Eye & ENT Hospital of Fudan University and Beijing Tongren Hospital, Capital Medical University). Eligible myopic patients scheduled for PIOL implantation were randomly assigned via a centralized dynamic randomization system to receive either the experimental aspheric PR PIOL or the control V4c implantable Collamer lens. At postoperative 1, 3, and 6 months, the efficacy index (primary endpoint: proportion achieving≥0.8 at 6 months), safety index, uncorrected distance/near visual acuity, best-corrected distance visual acuity, vault, intraocular pressure, corneal endothelial cell density, visual symptoms, and complications of the two groups were compared, with statistical analyses using the independent t-tests and chi-square tests.

Results

The study enrolled 187 myopic patients (187 eyes), including 47 males (47 eyes) and 140 females (140 eyes), with a mean age of (28.60±5.08) years (range: 25 to 32 years). The experimental group included 91 patients, while the control group included 96 patients. At 6 months postoperatively, the efficacy index was 1.12±0.24 and 1.14±0.21, and the safety index was 1.28±0.26 and 1.26±0.23 in the experimental group and the control group, respectively, with no statistically significant differences between the two groups (both P>0.05). The difference in primary endpoint achievement rates was -1.19% [98.81% (83/84) in the experimental group vs. 100% (86/86) in controls], which exceeded the non-inferiority margin of -10%, demonstrating non-inferiority of the experimental intervention. At 6 months, the experimental group demonstrated uncorrected distance visual acuity of -0.01±0.09 logMAR compared to -0.03±0.08 logMAR in the control group, while best-corrected distance visual acuity was measured at -0.06±0.07 logMAR versus -0.08±0.06 logMAR, with no statistically significant differences observed between groups (both P>0.05). Similarly, there were no statistically significant intergroup differences in intraocular pressure and corneal endothelial cell density (both P>0.05). At both 1 month and 6 months postoperatively, the differences were significant between the two groups in the central vault and the peripheral-central vault difference (all P<0.05); however, no statistically significant difference in the peripheral vault was observed between groups (both P>0.05). At 1 month postoperatively, the incidence of glare in the experimental group [24.72% (22/89)] was significantly lower than that in the control group [54.26% (51/94)] (P<0.05). And there were no statistically significant differences between the two groups in the incidence of other visual symptoms including diplopia, ghosting, and blurred vision (all P>0.05). During the 6-month follow-up period, neither group exhibited any postoperative complications.

Conclusion

Aspheric PIOL implantation shows favorable 6-month safety/efficacy and visual quality in myopia correction, though long-term outcomes warrant further investigations.

Для цитирования: Wang X Y, Dong Z, Xiong Y, Li Y, Luo Y, Yang Y B, Liu L, Lin D, Wang Z, Xiong L, Zhang G B, Zhang Q S, Zhou X T, Wang N L. [Safety and efficacy of aspheric phakic IOL implantation in myopia: short-term clinical results].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2025. DOI: 10.3760/cma.j.cn112142-20250421-00192.