MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.b.35149

Медицинская библиотека · Journal of biomedical materials research. Part B, Applied biomaterials · 2022

Detailed insight into chromium species released from failed CoCrMo implants: Ex vivo periprosthetic tissues study.

Pechancová Radka, Gallo Jiří, Baron Daniel, Milde David, Antal Peter, Slobodová Zuzana, Lemr Karel, Pluháček Tomáš

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This unique study provides information on Cr species and their distribution in periprosthetic tissues of patients with metal-on-polyethylene joint implants. Co-Cr-Mo alloy has been widely used in joint replacement and represents a source of metal derived species. In the case of chromium, previous studies on periprosthetic tissues revealed mainly Cr(III) distribution, whereas the potential release of carcinogenic Cr(VI) species has been still a subject of debate. Here, an analytical approach utilizing speciation and fractionation was developed to analyze periprosthetic tissue samples collected from wide range of patients with failed total hip or knee replacements. The results reveal that Cr(III) is mainly released in the form of insoluble CrPO4 and Cr2 O3 particles. The highest Cr contents were found in periprosthetic tissues of patients suffering from aseptic loosening and having more Cr-based implants in the body. Cr species penetrated tissue layers, but their levels decreased with the distance from an implant. The detailed speciation/fractionation study carried out using the set of consecutive periprosthetic tissues of a patient with extensive metallosis showed the presence of trace amounts of free Cr(III), nanoparticles, and metal-protein complexes, but the majority of Cr still occurred in CrPO4 form. Carcinogenic Cr(VI) species were not detected. Up to date, there is no published human tissue study focused on the detailed speciation of both soluble and insoluble Cr-based species in the context of failing total hip and knee replacements.

Для цитирования: Pechancová Radka, Gallo Jiří, Baron Daniel, Milde David, Antal Peter, Slobodová Zuzana, Lemr Karel, Pluháček Tomáš. Detailed insight into chromium species released from failed CoCrMo implants: Ex vivo periprosthetic tissues study.. Journal of biomedical materials research. Part B, Applied biomaterials. 2022. DOI: 10.1002/jbm.b.35149.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.