MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rct.0000000000001297

Медицинская библиотека · Journal of computer assisted tomography · 2022

Diagnostic Value of Advanced Metal Artifact Reduction Magnetic Resonance Imaging for Periprosthetic Joint Infection.

Inaoka Tsutomu, Kitamura Noriko, Sugeta Masayuki, Nakatsuka Tomoya, Ishikawa Rumiko, Kasuya Shusuke, Sugiura Yoshiya, Nakajima Arata, Nakagawa Koichi, Terada Hitoshi

СтатьяПеревод пока не подготовлен

Аннотация

MATERIALS AND

METHODS

Magnetic resonance imaging around metal joint prostheses including multiacquisition variable-resonance image combination selective at 1.5 T (from April 2014 to August 2020) was retrospectively evaluated by 2 radiologists for detection of abnormal findings (joint effusion, capsular thickening, pericapsular edema, soft-tissue fluid collection, soft-tissue edema, bone marrow edema pattern around the implant [BME pattern], lymphadenopathy, and others) and overall image impression for PJI. Regarding the soft-tissue fluid collection, presence of communication to the joint or capsular-like structure was evaluated. Clinical assessments were recorded. Positive predictive values (PPVs), negative predictive values (NPVs), and odds ratios (ORs) for PJI were calculated for the abnormal findings. Overall image impression for PJI was evaluated. χ2, Fisher exact, t, and Mann-Whitney U tests and receiver operating characteristic analysis were used. Interobserver agreement was assessed with κ statistics.

RESULTS

Forty-three joints in 36 patients (mean ± SD age, 75.4 ± 8.8 years; 30 women; hip [n = 29], knee [n = 12], and elbow [n = 2]) were evaluated. Eighteen joints (42%) were clinically diagnosed as PJI. The findings suggesting PJI were capsular thickening (PPV, 70%; NPV, 90%; OR, 20.6), soft-tissue fluid collection (PPV, 81%; NPV, 81%; OR, 19.1), soft-tissue edema (PPV, 67%; NPV, 89%; OR, 17), pericapsular edema (PPV, 76%; NPV, 81%; OR, 13.7), and joint effusion (PPV, 55%; NPV, 100%; OR, 12). Soft-tissue fluid collection without capsular-like structure (PPV, 83%; NPV, 74%; OR, 14.4) or with communication to the joint (PPV, 75%; NPV, 71%; OR, 7.3) suggested PJI. The combinations of joint effusion, capsular thickening, pericapsular edema, soft-tissue fluid collection, and soft-tissue edema highly suggested PJI. Regarding the BME pattern, the combination with soft-tissue edema raised the possibility of PJI (PPV, 73%; NPV, 69%; OR, 5.9). Regarding the interobserver agreements for each abnormal finding, κ values were 0.60 to 0.77. Regarding the overall image impression, weighted κ value was 0.97 and areas under the receiver operating characteristic curve were 0.949 (95% confidence interval, 0.893-1.005) and 0.926 (95% confidence interval, 0.860-0.991) with no significant difference (P = 0.534).

CONCLUSIONS

The findings suggesting PJI were capsular thickening, soft-tissue fluid collection, soft-tissue edema, pericapsular edema, and joint effusion. The combinations of them highly suggested PJI. Regarding the BME pattern, the combination with soft-tissue edema raised the possibility of PJI.

Для цитирования: Inaoka Tsutomu, Kitamura Noriko, Sugeta Masayuki, Nakatsuka Tomoya, Ishikawa Rumiko, Kasuya Shusuke, Sugiura Yoshiya, Nakajima Arata, Nakagawa Koichi, Terada Hitoshi. Diagnostic Value of Advanced Metal Artifact Reduction Magnetic Resonance Imaging for Periprosthetic Joint Infection.. Journal of computer assisted tomography. 2022. DOI: 10.1097/rct.0000000000001297.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.