International forum of allergy & rhinology · 2021
Psychometric properties of the brief version of the questionnaire of olfactory disorders in patients with chronic rhinosinusitis.
СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mattos Jose L, Bodner Todd E, Mace Jess C, Schlosser Rodney J, Beswick Daniel M, Ramakrishnan Vijay R, Alt Jeremiah A, Payne Spencer C, Smith Timothy L, Soler Zachary M
Аннотация
BACKGROUND: The Questionnaire of Olfactory Disorders-Negative Statements (QOD-NS) is a 17-item instrument measuring olfactory-specific quality of life (QOL). However, in clinical research patients can be overwhelmed with multiple questionnaires. We recently developed the 7-item brief QOD-NS (B-QOD). Our objective was to evaluate the psychometric properties of the B-QOD in both the development (D) sample, and in a separate replication (R) sample.
METHODS: Testing on D (n = 203) and R (n = 281) samples included initial exploratory factor analysis (EFA), followed by internal reliability, information loss, and confirmatory factor analysis (CFA). Finally, incremental predictive utility analysis (IPUA) was performed by correlating the B-QOD with the 22-item Sino-Nasal Outcome Test (SNOT-22) survey.
RESULTS: EFAs of both D and R demonstrated an underlying single-factor structure (eigenvalue = 4.17 and 3.57, respectively) with comparable loading factors (R > 0.30 for both). B-QOD also had good internal reliability in both D and R (Cronbach's alpha = 0.88 and 0.83, respectively). Also, there is minimal information loss with B-QOD compared to QOD-NS in both D and R (R = 0.98 and 0.96, respectively). CFA indicates that the B-QOD single-factor model has good overall fit as measured by the Comparative Fit Index (CFI) and the Standardized Root Mean Squared Residuals (SRMSR) in the D and R samples (CFI = 0.99 and 0.97; SRMSR = 0.035 and 0.053). IPUA shows that the QOD-NS offers no additional predictive benefit of SNOT-22 scores when compared with B-QOD.
CONCLUSION: The 7-item B-QOD captures a structurally coherent and reliable single dimension, with minimal information loss and excellent external predictive utility when compared to the QOD-NS.
METHODS: Testing on D (n = 203) and R (n = 281) samples included initial exploratory factor analysis (EFA), followed by internal reliability, information loss, and confirmatory factor analysis (CFA). Finally, incremental predictive utility analysis (IPUA) was performed by correlating the B-QOD with the 22-item Sino-Nasal Outcome Test (SNOT-22) survey.
RESULTS: EFAs of both D and R demonstrated an underlying single-factor structure (eigenvalue = 4.17 and 3.57, respectively) with comparable loading factors (R > 0.30 for both). B-QOD also had good internal reliability in both D and R (Cronbach's alpha = 0.88 and 0.83, respectively). Also, there is minimal information loss with B-QOD compared to QOD-NS in both D and R (R = 0.98 and 0.96, respectively). CFA indicates that the B-QOD single-factor model has good overall fit as measured by the Comparative Fit Index (CFI) and the Standardized Root Mean Squared Residuals (SRMSR) in the D and R samples (CFI = 0.99 and 0.97; SRMSR = 0.035 and 0.053). IPUA shows that the QOD-NS offers no additional predictive benefit of SNOT-22 scores when compared with B-QOD.
CONCLUSION: The 7-item B-QOD captures a structurally coherent and reliable single dimension, with minimal information loss and excellent external predictive utility when compared to the QOD-NS.