Audiologic, surgical and subjective outcomes of active transcutaneous bone conduction implant system (Bonebridge).

Oh Se-Joon, Goh Eui-Kyung, Choi Sung-Won, Lee Seokhwan, Lee Hyun-Min, Lee Il-Woo, Kong Soo-Keun

СтатьяПеревод пока не подготовлен

Аннотация

Objective

Our objective was to evaluate the surgical restrictions, audiologic benefits and satisfaction from using an active transcutaneous bone conduction device (BCD), Bonebridge® (BB) in patients with mixed/conductive hearing loss (MCHL) or single-sided deafness (SSD).

Design

A retrospective review from all patients who underwent BB surgery at the Pusan National University Hospital from 2015 to 2017 for SSD or MCHL was performed.Study sample: Twenty-two patients with SSD and five with MCHL had a BB implanted and analysed.

Results

Complete transmastoid implantation of the device was possible for all patients with an intact canal wall (ICW), using lifts if necessary. The overall functional hearing gain (FHG) in SSD and MCHL was 31.4 and 37.6 dB, respectively. The mean percentage of speech recognition in a quiet was 81% (vs. 11% unaided) for MCHL group and 82% (vs. 29% unaided) for SSD group. Mean speech recognition scores in noise improved significantly under various signal-to-noise ratio (SNR) for both groups. Questionnaires showed overall improvement, and there was no significant difference between the two groups.

Conclusions

The BB provides improved functional gain, and there were no limitations during surgery despite the large device. Both MCHL and SSD group had benefit and improved quality of life with BB.

Для цитирования: Oh Se-Joon, Goh Eui-Kyung, Choi Sung-Won, Lee Seokhwan, Lee Hyun-Min, Lee Il-Woo, Kong Soo-Keun. Audiologic, surgical and subjective outcomes of active transcutaneous bone conduction implant system (Bonebridge).. International journal of audiology. 2019. DOI: 10.1080/14992027.2019.1657242.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.